SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sundström Nina)
 

Sökning: WFRF:(Sundström Nina) > Novel, clinically a...

Novel, clinically applicable method to measure step-width during the swing phase of gait

Bäcklund, Tomas (författare)
Umeå universitet,Radiofysik
Öhberg, Fredrik, 1969- (författare)
Umeå universitet,Radiofysik
Johansson, Gudrun (författare)
Umeå universitet,Institutionen för samhällsmedicin och rehabilitering
visa fler...
Grip, Helena (författare)
Umeå universitet,Radiofysik
Sundström, Nina (författare)
Umeå universitet,Radiofysik
visa färre...
 (creator_code:org_t)
2020-06-30
2020
Engelska.
Ingår i: Physiological Measurement. - : Institute of Physics Publishing (IOPP). - 0967-3334 .- 1361-6579. ; 41:6
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: Step-width during walking is an indicator of stability and balance in patients with neurological disorders, and development of objective tools to measure this clinically would be a great advantage. The aim of this study was to validate an in-house-developed gait analysis system (Striton), based on optical and inertial sensors and a novel method for stride detection, for measuring step-width during the swing phase of gait and temporal parameters.Approach: The step-width and stride-time measurements were validated in an experimental setup, against a 3D motion capture system and on an instrumented walkway. Further, test-retest and day-to-day variability were evaluated, and gait parameters were collected from 87 elderly persons (EP) and four individuals with idiopathic normal pressure hydrocephalus (iNPH) before/after surgery.Main results: Accuracy of the step-width measurement was high: in the experimental setup mean error was 0.08 +/- 0.25 cm (R = 1.00) and against the 3D motion capture system 0.04 +/- 1.12 cm (R = 0.98). Test-retest and day-to-day measurements were equal within +/- 0.5 cm. Mean difference in stride time was -0.003 +/- 0.008 s between Striton and the instrumented walkway. The Striton system was successfully applied in the clinical setting on individuals with iNPH, which had larger step-width (6.88 cm, n = 4) compared to EP (5.22 cm, n = 87).Significance: We conclude that Striton is a valid, reliable and wearable system for quantitative assessment of step-width and temporal parameters during gait. Initial measurements indicate that the newly defined step-width parameter differs between EP and patients with iNPH and before/after surgery. Thus, there is potential for clinical applicability in patients with reduced gait stability.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Neurovetenskaper (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Neurosciences (hsv//eng)

Nyckelord

gait
swing phase
step-width
inertial measurement unit
wearable
optical sensor

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy