SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Andersson Nina)
 

Sökning: WFRF:(Andersson Nina) > Assessment of cereb...

Assessment of cerebrospinal fluid outflow conductance using an adaptive observer-experimental and clinical evaluation

Andersson, Kennet, 1979- (författare)
Umeå universitet,Radiofysik
Manchester, Ian R (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik
Andersson, Nina (författare)
Umeå universitet,Radiofysik
visa fler...
Shiriaev, Anton (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik
Malm, Jan (författare)
Umeå universitet,Neurologi
Eklund, Anders (författare)
Umeå universitet,Radiofysik
visa färre...
 (creator_code:org_t)
2007-10-05
2007
Engelska.
Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 28:11, s. 1355-1368
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Idiopathic normal pressure hydrocephalus (INPH) patients have a disturbance in the dynamics of the cerebrospinal fluid (CSF) system. The outflow conductance, C, of the CSF system has been suggested to be prognostic for positive outcome after treatment with a CSF shunt. All current methods for estimation of C have drawbacks; these include lack of information on the accuracy and relatively long investigation times. Thus, there is a need for improved methods. To accomplish this, the theoretical framework for a new adaptive observer (OBS) was developed which provides real-time estimation of C. The aim of this study was to evaluate the OBS method and to compare it with the constant pressure infusion (CPI) method. The OBS method was applied to data from infusion investigations performed with the CPI method. These consisted of repeated measurements on an experimental set-up and 30 patients with suspected INPH. There was no significant difference in C between the CPI and the OBS method for the experimental set-up. For the patients there was a significant difference, −0.84 ± 1.25 µl (s kPa)−1, mean ± SD (paired sample t-test, p < 0.05). However, such a difference is within clinically acceptable limits. This encourages further development of this new real-time approach for estimation of the outflow conductance.

Nyckelord

Normal pressure hydrocephalus
outflow conductance
adaptive observer
real-time estimation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy