Registration of histopathology to magnetic resonance imaging of prostate cancer

Sandgren, Kristina (författare)
Umeå universitet,Radiofysik
Nilsson, Erik (författare)
Umeå universitet,Radiofysik
Keeratijarut Lindberg, Angsana (författare)
Umeå universitet,Radiofysik
visa fler...
Strandberg, Sara, 1976- (författare)
Umeå universitet,Diagnostisk radiologi
Blomqvist, Lennart (författare)
Karolinska Institutet
Bergh, Anders (författare)
Umeå universitet,Patologi
Friedrich, Bengt (författare)
Umeå universitet,Urologi och andrologi
Axelsson, Jan, 1966- (författare)
Umeå universitet,Radiofysik
Ögren, Margareta (författare)
Umeå universitet,Diagnostisk radiologi
Ögren, Mattias (författare)
Umeå universitet,Diagnostisk radiologi
Widmark, Anders (författare)
Umeå universitet,Onkologi
Thellenberg-Karlsson, Camilla, 1972- (författare)
Umeå universitet,Onkologi
Söderström, Karin (författare)
Umeå universitet,Onkologi
Riklund, Katrine, MD, PhD, Professor, 1963- (författare)
Umeå universitet,Diagnostisk radiologi
Jonsson, Joakim, 1984- (författare)
Umeå universitet,Radiofysik
Nyholm, Tufve (författare)
Umeå universitet,Radiofysik
Söderkvist, K (författare)
visa färre...
 (creator_code:org_t)
Elsevier, 2021
2021
Engelska.
Ingår i: Physics and Imaging in Radiation Oncology. - : Elsevier. - 2405-6316. ; 18, s. 19-25
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background and purpose: The diagnostic accuracy of new imaging techniques requires validation, preferably by histopathological verification. The aim of this study was to develop and present a registration procedure between histopathology and in-vivo magnetic resonance imaging (MRI) of the prostate, to estimate its uncertainty and to evaluate the benefit of adding a contour-correcting registration.Materials and methods: For twenty-five prostate cancer patients, planned for radical prostatectomy, a 3D-printed prostate mold based on in-vivo MRI was created and an ex-vivo MRI of the specimen, placed inside the mold, was performed. Each histopathology slice was registered to its corresponding ex-vivo MRI slice using a 2D-affine registration. The ex-vivo MRI was rigidly registered to the in-vivo MRI and the resulting transform was applied to the histopathology stack. A 2D deformable registration was used to correct for specimen distortion concerning the specimen's fit inside the mold. We estimated the spatial uncertainty by comparing positions of landmarks in the in-vivo MRI and the corresponding registered histopathology stack.Results: Eighty-four landmarks were identified, located in the urethra (62%), prostatic cysts (33%), and the ejaculatory ducts (5%). The median number of landmarks was 3 per patient. We showed a median in-plane error of 1.8 mm before and 1.7 mm after the contour-correcting deformable registration. In patients with extraprostatic margins, the median in-plane error improved from 2.1 mm to 1.8 mm after the contour-correcting deformable registration.Conclusions: Our registration procedure accurately registers histopathology to in-vivo MRI, with low uncertainty. The contour-correcting registration was beneficial in patients with extraprostatic surgical margins.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Histopathology correlation
Image registration
PET/MRI
Prostate cancer

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy