SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Grip Helena)
 

Search: WFRF:(Grip Helena) > Single sensor measu...

  • Bäcklund, Tomas,1958-Umeå universitet,Radiofysik (author)

Single sensor measurement of heel-height during the push-off phase of gait

  • Article/chapterEnglish2021

Publisher, publication year, extent ...

  • 2021-11-26
  • Institute of Physics (IOP),2021
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:umu-182776
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-182776URI
  • https://doi.org/10.1088/1361-6579/ac325cDOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Previously included in thesis in manuscript form. 
  • Objective: In healthy gait a forceful push-off is needed to get an efficient leg swing and propulsion, and a high heel lift makes a forceful push-off possible. The power of the push-off is decreased with increased age and in persons with impaired balance and gait. The aim of this study was to evaluate whether a wearable equipment (Striton) and algorithms to estimate vertical heel-height during gait from a single optical distance sensor is reliable and feasible for clinical applications.Approach: To assess heel-height with the Striton system an optical distance sensor was used to measure the distance to the floor along the shank. An algorithm was created to transform this measure to a vertical distance. The heel-height was validated in an experimental setup, against a 3D motion capture system (MCS), and test-retest and day-to-day tests were performed on 10 elderly persons. As a reference material 83 elderly persons were included, and heel-height was measured before and after surgery in four patients with the neurological disorder idiopathic normal pressure hydrocephalus (iNPH).Main results: In the experimental setup the accuracy was high with a maximum error of 2% at all distances, target colours and inclination angles, and the correlation to the MCS was R = 0.94. Test-retest and day-to-day tests were equal within ±1.2 cm. Mean heel-height of the elderly persons was 16.5 ± 0.6 cm and in the patients with iNPH heel-height was increased from 11.2 cm at baseline to 15.3 cm after surgery.Significance: Striton can reliably measure heel-height during gait, with low test-retest and day-to-day variability. The system was easy to attach, and simple to use, which makes it suitable for clinical applications.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Grip, HelenaUmeå universitet,Radiofysik(Swepub:umu)heagrp96 (author)
  • Öhberg, Fredrik,1969-Umeå universitet,Radiofysik(Swepub:umu)froh0003 (author)
  • Sundström, NinaUmeå universitet,Radiofysik(Swepub:umu)nian0004 (author)
  • Umeå universitetRadiofysik (creator_code:org_t)

Related titles

  • In:Physiological Measurement: Institute of Physics (IOP)42:100967-33341361-6579

Internet link

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Bäcklund, Tomas, ...
Grip, Helena
Öhberg, Fredrik, ...
Sundström, Nina
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
Articles in the publication
Physiological Me ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view