SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Efstathopoulos Efstathios)
 

Sökning: WFRF:(Efstathopoulos Efstathios) > Dosimetric quantiti...

Dosimetric quantities and effective dose in medical imaging : a summary for medical doctors

Vano, Eliseo (författare)
Radiology Department, Complutense University, Madrid, Spain
Frija, Guy (författare)
Université de Paris, 12 Rue de l’École de Médecine, Paris, France
Loose, Reinhard (författare)
Institute of Medical Physics, Hospital Nuremberg, Prof.-Ernst-Nathan-Str. 1, Nuremberg, Germany
visa fler...
Paulo, Graciano (författare)
ESTESC-Coimbra Health School, Medical Imaging and Radiotherapy Department, Instituto Politécnico de Coimbra, Rua 5 de Outubro, S. Martinho Do Bispo, Coimbra, Portugal
Efstathopoulos, Efstathios (författare)
2Nd Department of Radiology, Medical Physics Unit, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece
Granata, Claudio (författare)
Department of Paediatric Radiology, Institute for Maternal and Child Health - IRCCS “Burlo Garofolo”, Trieste, Italy
Andersson, Jonas, 1975- (författare)
Umeå universitet,Radiofysik
visa färre...
 (creator_code:org_t)
2021-07-13
2021
Engelska.
Ingår i: Insights into Imaging. - : Springer Berlin/Heidelberg. - 1869-4101. ; 12:1
  • Forskningsöversikt (refereegranskat)
Abstract Ämnesord
Stäng  
  • This review presents basic information on the dosimetric quantities used in medical imaging for reporting patient doses and establishing diagnostic reference levels. The proper use of the radiation protection quantity “effective dose” to compare doses delivered by different radiological procedures and different imaging modalities with its uncertainties and limitations, is summarised. The estimates of population doses required by the European Directive on Basic Safety Standards is commented on. Referrers and radiologists should be familiar with the dose quantities to inform patients about radiation risks and benefits. The application of effective dose on the cumulative doses from recurrent imaging procedures is also discussed.Patient summary: Basic information on the measurement units (dosimetric quantities) used in medical imaging for reporting radiation doses should be understandable to patients. The Working Group on “Dosimetry for imaging in clinical practice” recommended that a brief explanation on the used dosimetric quantities and units included in the examination imaging report, should be available for patients. The use of the quantity “effective dose” to compare doses to which patients are exposed to from different radiological procedures and its uncertainties and limitations, should also be explained in plain language. This is also relevant for the dialog on to the cumulative doses from recurrent imaging procedures. The paper summarises these concepts, including the need to estimate the population doses required by the European Directive on Basic Safety Standards. Referrers and radiologists should be familiar with the dose quantities to inform patients about radiation risks and benefits.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Cumulative dose
Diagnostic reference levels
Dosimetric quantities
Effective dose
Patient information

Publikations- och innehållstyp

ref (ämneskategori)
for (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy