SwePub
Sök i LIBRIS databas

  Extended search

L773:1873 376X
 

Search: L773:1873 376X > Feasibility and rel...

  • Claeson, Anna-Sara,1974-Umeå universitet,Institutionen för psykologi (author)

Feasibility and reliability of measures of bioactive lipids in human plasma and nasal mucosa

  • Article/chapterEnglish2022

Publisher, publication year, extent ...

  • Elsevier,2022
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:umu-199602
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-199602URI
  • https://doi.org/10.1016/j.jchromb.2022.123357DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Analysis of bioactive lipids is increasingly useful in clinical studies, and there is a need for non-invasive and easy-to-use sampling methods that meet the demands of reliability. Samples that can be taken by a non-professional and that can be taken repeatedly so as to provide more detailed information about the inflammatory process are often desired. In this study, the feasibility of non-invasive sampling of nasal mucosa and saliva for the analysis of bioactive lipid mediators (e.g. oxylipins and endocannabinoids) was evaluated in a pilot study (n = 10). In a second study, the reliability (relative and absolute) of sampling of these lipid mediators derived from nasal mucosa and from plasma was assessed by calculation of the intraclass correlation coefficient and Bland–Altman’s limit of agreement. Samples were taken at the same time of day on two occasions from a cohort of individuals with and without building-related intolerance (n = 37). Nasal mucosa proved to be a suitable matrix for the analysis of bioactive lipids and was therefore included in the study on reliability together with the plasma samples. Relative reliability varied among the identified oxylipins and endocannabinoids. Arachidonic acid derivatives showed generally better reliability. Absolute reliability measures also varied indicating that only a subset of the oxylipins and endocannabinoids were suitable as biomarkers in either nasal mucosa or plasma and should therefore be used with caution for that purpose.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Lindberg, Richard H.Umeå universitet,Kemiska institutionen(Swepub:umu)rili0003 (author)
  • Gouveia-Figueira, Sandra (author)
  • Nording, Malin L.,1976-Umeå universitet,Kemiska institutionen(Swepub:umu)mano0003 (author)
  • Umeå universitetInstitutionen för psykologi (creator_code:org_t)

Related titles

  • In:Journal of chromatography. B: Elsevier12061570-02321873-376X

Internet link

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view