SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1473 5628
 

Sökning: L773:1473 5628 > Reliability and val...

Reliability and validity of visual analysis of [18F]FE-PE2I PET/CT in early Parkinsonian disease

af Bjerkén, Sara (författare)
Umeå universitet,Institutionen för integrativ medicinsk biologi (IMB),Neurovetenskaper
Axelsson, Jan, 1966- (författare)
Umeå universitet,Radiofysik,Umeå centrum för funktionell hjärnavbildning (UFBI)
Larsson, Anne (författare)
Umeå universitet,Diagnostisk radiologi
visa fler...
Flygare, Carolina (författare)
Umeå universitet,Diagnostisk radiologi
Remes, Jussi (författare)
Umeå universitet,Diagnostisk radiologi
Strandberg, Sara, 1976- (författare)
Umeå universitet,Diagnostisk radiologi
Eriksson, Linda (författare)
Umeå universitet,Neurovetenskaper
Bäckström, David C., M.D. 1978- (författare)
Umeå universitet,Neurovetenskaper
Jakobson Mo, Susanna, Medicine Doktor, 1968- (författare)
Umeå universitet,Diagnostisk radiologi,Umeå centrum för funktionell hjärnavbildning (UFBI)
visa färre...
 (creator_code:org_t)
2023-03-03
2023
Engelska.
Ingår i: Nuclear medicine communications. - : Wolters Kluwer. - 0143-3636 .- 1473-5628. ; 44:5, s. 397-406
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: [18F]FE-PE2I (FE-PE2I) is a new radiotracer for dopamine transporter (DAT) imaging with PET. The aim of this study was to evaluate the visual interpretation of FE-PE2I images for the diagnosis of idiopathic Parkinsonian syndrome (IPS). The inter-rater variability, sensitivity, specificity, and diagnostic accuracy for visual interpretation of striatal FE-PE2I compared to [123I]FP-CIT (FP-CIT) single-photon emission computed tomography (SPECT) was evaluated.Methods: Thirty patients with newly onset parkinsonism and 32 healthy controls with both an FE-PE2I and FP-CIT were included in the study. Four patients had normal DAT imaging, of which three did not fulfil the IPS criteria at the clinical reassessment after 2 years. Six raters evaluated the DAT images blinded to the clinical diagnosis, interpreting the image as being ‘normal’ or ‘pathological’, and assessed the degree of DAT-reduction in the caudate and putamen. The inter-rater agreement was assessed with intra-class correlation and Cronbach’s α. For calculation of sensitivity and specificity, DAT images were defined as correctly classified if categorized as normal or pathological by ≥4/6 raters.Results: The overall agreement in visual evaluation of the FE-PE2I- and FP-CIT images was high for the IPS patients (α = 0.960 and 0.898, respectively), but lower in healthy controls (FE-PE2I: α = 0.693, FP-CIT: α = 0.657). Visual interpretation gave high sensitivity (both 0.96) but lower specificity (FE-PE2I: 0.86, FP-CIT: 0.63) with an accuracy of 90% for FE-PE2I and 77% for FP-CIT.Conclusion: Visual evaluation of FE-PE2I PET imaging demonstrates high reliability and diagnostic accuracy for IPS.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

[18F]FE-PE2I PET/computed tomography
diagnostic accuracy
early disease
Parkinson’s disease
PET
Radiology
radiologi
Neurology
neurologi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng