Systematic variability in ICG recordings results in ICG complex subtypes : steps towards the enhancement of ICG characterization

Benouar, Sara (författare)
Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria; Department of Textile Technology University of Borås, Borås, Sweden
Hafid, Abdelakram (författare)
Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria; Department of Textile Technology University of Borås, Borås, Sweden
Attari, Mokhtar (författare)
Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria
visa fler...
Kedir-Talha, Malika (författare)
Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria
Seoane, Fernando (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2018-12-19
2018
Engelska.
Ingår i: Journal of Electrical Bioimpedance. - : Walter de Gruyter. - 1891-5469. ; 9:1, s. 72-82
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The quality of an impedance cardiography (ICG) signal critically impacts the calculation of hemodynamic parameters. These calculations depend solely on the identification of ICG characteristic points on the ABEXYOZ complex. Unfortunately, contrary to the relatively constant morphology of the PQRST complex in electrocardiography, the waveform morphology of ICG data is far from stationary, which causes difficulties in the accuracy of the automated detection of characteristic ICG points. This study evaluated ICG recordings obtained from 10 volunteers. The results indicate that there are several different waveforms for the ABEXYOZ complex; there are up to five clearly distinct waveforms for the ABEXYOZ complex in addition to those that are typically reported. The differences between waveform types increased the difficulty of detecting ICG points. To accurately detect all ICG points, the ABEXYOZ complex should be analyzed according to the corresponding waveform type.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Annan teknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Other Engineering and Technologies (hsv//eng)

Nyckelord

bioimpedance
impedance cardiography
dZ/dt signal
ABEXYOZ complex
characteristic points
waveform analysis

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy