Region of interest focused MRI to synthetic CT translation using regression and segmentation multi-task network

Kaushik, Sandeep S. (författare)
GE Healthcare, Munich, Germany; Department of Quantitative Biomedicine, University of Zurich, Zurich, Switzerland
Bylund, Mikael (författare)
Umeå universitet,Institutionen för strålningsvetenskaper
Cozzini, Cristina (författare)
GE Healthcare, Munich, Germany
visa fler...
Shanbhag, Dattesh (författare)
GE Healthcare, Bangalore, India
Petit, Steven F. (författare)
Department of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, Netherlands
Wyatt, Jonathan J. (författare)
Translational and Clinical Research Institute, Newcastle University and Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, United Kingdom
Menzel, Marion I. (författare)
GE Healthcare, Munich, Germany; Dept. of Physics, Technical University of Munich, Munich, Germany
Pirkl, Carolin (författare)
GE Healthcare, Munich, Germany
Mehta, Bhairav (författare)
GE Healthcare, Bangalore, India
Chauhan, Vikas (författare)
Sree Chitra Tirunal Institute of Medical Sciences and Technology (SCTIMST), Trivandrum, India
Chandrasekharan, Kesavadas (författare)
Sree Chitra Tirunal Institute of Medical Sciences and Technology (SCTIMST), Trivandrum, India
Jonsson, Joakim, 1984- (författare)
Umeå universitet,Institutionen för strålningsvetenskaper
Nyholm, Tufve (författare)
Umeå universitet,Institutionen för strålningsvetenskaper
Wiesinger, Florian (författare)
GE Healthcare, Munich, Germany
Menze, Bjoern (författare)
Department of Quantitative Biomedicine, University of Zurich, Zurich, Switzerland
visa färre...
 (creator_code:org_t)
Institute of Physics (IOP), 2023
2023
Engelska.
Ingår i: Physics in Medicine and Biology. - : Institute of Physics (IOP). - 0031-9155 .- 1361-6560. ; 68:19
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: In MR-only clinical workflow, replacing CT with MR image is of advantage for workflow efficiency and reduces radiation to the patient. An important step required to eliminate CT scan from the workflow is to generate the information provided by CT via an MR image. In this work, we aim to demonstrate a method to generate accurate synthetic CT (sCT) from an MR image to suit the radiation therapy (RT) treatment planning workflow. We show the feasibility of the method and make way for a broader clinical evaluation.Approach: We present a machine learning method for sCT generation from zero-echo-time (ZTE) MRI aimed at structural and quantitative accuracies of the image, with a particular focus on the accurate bone density value prediction. The misestimation of bone density in the radiation path could lead to unintended dose delivery to the target volume and results in suboptimal treatment outcome. We propose a loss function that favors a spatially sparse bone region in the image. We harness the ability of the multi-task network to produce correlated outputs as a framework to enable localization of region of interest (RoI) via segmentation, emphasize regression of values within RoI and still retain the overall accuracy via global regression. The network is optimized by a composite loss function that combines a dedicated loss from each task.Main results: We have included 54 brain patient images in this study and tested the sCT images against reference CT on a subset of 20 cases. A pilot dose evaluation was performed on 9 of the 20 test cases to demonstrate the viability of the generated sCT in RT planning. The average quantitative metrics produced by the proposed method over the test set were-(a) mean absolute error (MAE) of 70 ± 8.6 HU; (b) peak signal-to-noise ratio (PSNR) of 29.4 ± 2.8 dB; structural similarity metric (SSIM) of 0.95 ± 0.02; and (d) Dice coefficient of the body region of 0.984 ± 0.Significance: We demonstrate that the proposed method generates sCT images that resemble visual characteristics of a real CT image and has a quantitative accuracy that suits RT dose planning application. We compare the dose calculation from the proposed sCT and the real CT in a radiation therapy treatment planning setup and show that sCT based planning falls within 0.5% target dose error. The method presented here with an initial dose evaluation makes an encouraging precursor to a broader clinical evaluation of sCT based RT planning on different anatomical regions.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

focused loss
image translation
MRI radiation therapy
multi-task CNN
synthetic CT

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy