Assessment of navigated pedicle screws from intraoperative imaging : a prospective study of accuracy and agreement

Åkerstedt, Josefin (författare)
Umeå universitet,Institutionen för kirurgisk och perioperativ vetenskap,Spine Unit, Department of Orthopedics, Umeå University Hospital, Umeå, Sweden
Berglund, Anders (författare)
Epistat AB, Statistical analysis, Uppsala Science Park, Uppsala, Sweden
Kolakowski, Przemyslaw (författare)
Spine Unit, Department of Orthopedics, Umeå University Hospital, Umeå, Sweden
visa fler...
Sliwinski, Piotr (författare)
Section of Neuroradiology, Regional Hospital of Sundsvall, Sundsvall, Sweden
Jablonski, Marcin (författare)
Section of Neuroradiology, Regional Hospital of Sundsvall, Sundsvall, Sweden
Bobinski, Lukas (författare)
Umeå universitet,Institutionen för kirurgisk och perioperativ vetenskap,Spine Unit, Department of Orthopedics, Umeå University Hospital, Umeå, Sweden
visa färre...
 (creator_code:org_t)
International Society for the Advancement of Spine Surgery (ISASS), 2023
2023
Engelska.
Ingår i: International Journal of Spine Surgery. - : International Society for the Advancement of Spine Surgery (ISASS). - 2211-4599. ; 17:5, s. 684-689
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Intraoperative (IO) image guidance surgery using 3-dimensional fluoroscopic navigation methods, such as the O-arm system, has improved the accuracy of pedicle screw placement in instrumented spine surgery. IO and postoperative (PO) validation of the implant’s correct position from radiological images is a decisive step to ensure patient safety and avoidance of complications related to implant misplacement. In this prospective single-center study, the authors investigated the accuracy and agreement of assessment of pedicle screws from IO O-arm images in comparison to PO computed tomography images. This study aimed to determine whether a final evaluation of pedicle screws can safely be conducted from IO images that supersede the PO computed tomography control.Methods: A prospective single-center study was carried out at the Spine Unit in the Department of Orthopedics at Umeå University Hospital between 2019 and 2021. All patients enrolled in the study underwent instrumented thoracolumbar spine surgery using navigation. Imaging data were obtained from IO and PO examinations. Four reviewers—2 attending senior spine surgeons, 1 final year resident in orthopedics, and 1 attending neuroradiologist—classified pedicle screws using the Gertzbein and Robbins classification system. Agreement and accuracy of the reviewers were studied to evaluate the assessment of pedicle screws from IO and PO images.Results: A total of 70 patients (422 screws) were included in the study. There was high accuracy among surgeons both on IO and PO images (0.96–0.97, 95% CI [0.94–0.99] and 0.97, 95% CI [0.94–0.99], respectively), and the overall agreement between all raters was 92% to 98% (95% CI [0.90, 1.00]). The discrepancy in assessment between optimal (Group 1) and suboptimal (Group 2) screws between IO and PO images was as low as 1% to 1.7%, which indicates that very few suboptimal screws are missed in the assessment of IO images.Conclusions: The assessment of navigated pedicle screws using IO images is safe and reliable and may replace the need for further assessment using PO imaging.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy