SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ljung Eric)
 

Sökning: WFRF:(Ljung Eric) > Detection of titani...

Detection of titanium in electrothermal atomizers by laser-induced fluorescence : Part 1. Determination of optimum excitation and detection wavelengths

Ljung, Per (författare)
Umeå universitet,Institutionen för fysik
Nyström, Eric (författare)
Umeå universitet,Institutionen för fysik
Enger, Jonas (författare)
The Analytical Laser Spectroscopy Group, Department of Physics, Chalmers University of Technology and The University of Göteborg, Göteborg, Sweden
visa fler...
Ljungberg, Peter (författare)
The Analytical Laser Spectroscopy Group, Department of Physics, Chalmers University of Technology and The University of Göteborg, Göteborg, Sweden
Axner, Ove (författare)
Umeå universitet,Institutionen för fysik
visa färre...
 (creator_code:org_t)
Elsevier, 1997
1997
Engelska.
Ingår i: Spectrochimica Acta Part B - Atomic Spectroscopy. - : Elsevier. - 0584-8547 .- 1873-3565. ; 52:6, s. 675-701
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A detailed investigation has been performed of suitable excitation and detection wavelengths of Ti for the technique of laser-induced fluorescence in electrothermal atomizers. Fluorescence spectra (most often in the 250-350 nm region) from the 39 excitation wavelengths conjectured to be the most important (in the 220-270 nm region) have been investigated in more detail by the use of an intensified CCD detector. The fluorescence spectra were found to have a rich occurrence of peaks (about 50 each), of which many cannot be found in existing atomic wavelength data in the literature. All of the peaks found (with one exception) could be identified thanks to a home-made program that calculates atomic wavelengths from existing energy level data. Most of the spectra are dominated by ''indirect'' transitions (i.e. fluorescence from an upper level that is different from the one accessed by the laser) despite the prediction of existing ''direct'' transitions. This indicates that the collisional redistribution processes amongst the excited levels, in general, are faster than typical fluorescence rates for Ti in graphite furnaces. Suitable excitation and detection wavelength combinations are given. One such suitable choice is excitation at 264.662 nm since the fluorescence following this excitation consisted of peaks of almost equal magnitude in three different wavelength regions (around 295, 319 and 338 nm).

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Nyckelord

laser-induced fluorescence
electrothermal atomizers
graphite furnace
LIF-GF
intensified charge coupled device
Ti
trace element analysis
charge-coupled-device
absorption spectrometry
tube atomization
trace amounts
resonance
thallium
lead
antimony
flames

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ljung, Per
Nyström, Eric
Enger, Jonas
Ljungberg, Peter
Axner, Ove
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
och Atom och molekyl ...
Artiklar i publikationen
Spectrochimica A ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy