SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Åberg Torkel)
 

Sökning: WFRF:(Åberg Torkel) > Clinical effects of...

Clinical effects of the heparin coated surface in cardiopulmonary bypass

Svenmarker, Staffan (författare)
Umeå universitet,Institutionen för kirurgisk och perioperativ vetenskap
Sandström, Erik (författare)
Karlsson, Thomas (författare)
visa fler...
Jansson, Erica (författare)
Lindholm, Ronny (författare)
Appelblad, Micael (författare)
Åberg, Torkel (författare)
visa färre...
 (creator_code:org_t)
Oxford University Press, 1997
1997
Engelska.
Ingår i: European Journal of Cardio-Thoracic Surgery. - : Oxford University Press. - 1010-7940 .- 1873-734X. ; 11:5, s. 957-964
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVE: In a randomised study of 120 patients, undergoing primary operation for coronary heart decease, two groups were investigated as regards to the effects of heparin coated cardiopulmonary bypass on brainfunction parameters and general clinical outcome. The study group (n = 56) was perfused using an extra-corporeal circuit treated with covalent bonded heparin; the control group (n = 59) used an identical set-up without heparin treatment. Systemic heparin doses were calculated to achieve ACT levels of 250 and 500 s, respectively. Postoperative course was evaluatedby examining a set of clinically relevant parameters including a detailed registry of postoperative deviations. Brain function was assessed by the biochemical marker S-100 and tests of memory performance.RESULTS: There were several signs of reduced operative trauma in the study group. Hospital stay was reduced by nearly 1 day (P < 0.05). Time on postoperative ventilatory support was approximately 4 h shorter (P = 0.009). Chest drain blood loss was decreased both at 8 (P = 0.01) and 24 h (P = 0.007) postoperatively. Body temperature was lower after surgery and especially on days 2 (P = 0.03) and 3 (P = 0.01). Perioperative creatinine elevation was significantly reduced (P = 0.03). Neurological deviations were fewer (P =0.01). Brain function assessment revealed reduced plasma levels of S- 100 both at termination of cardiopulmonary bypass (P = 0.008) and 7 h later (P= 0.04). However, no remediation of memory impairment could be demonstrated.CONCLUSIONS: Cardiopulmonary bypass with covalent bonded heparin attached to the extra-corporeal circuit in combination with a reduced systemic heparin dose seems to reduce safely and effectively the operative stress to the patient. There were also signs of improved cerebral protection.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

cardiopulmonary bypass
heparin
biocompatible materials
thoracic surgery
memory
nerve tissue protein S-100

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy