SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:umu-3055"
 

Sökning: onr:"swepub:oai:DiVA.org:umu-3055" > Determination of C-...

Determination of C-21 ketosteroids in serum using trifluoromethanesulfonic acid catalyzed precolumn dansylation and 1,1’-oxalyldiimidazole postcolumn peroxyoxalate chemiluminescence detection

Appelblad, Patrik (författare)
Umeå universitet,Institutionen för klinisk vetenskap,Kemiska institutionen
Jonsson, Tobias (författare)
Umeå universitet,Kemiska institutionen
Bäckström, Torbjörn (författare)
Umeå universitet,Obstetrik och gynekologi
visa fler...
Irgum, Knut (författare)
Umeå universitet,Kemiska institutionen
visa färre...
 (creator_code:org_t)
1998-10-24
1998
Engelska.
Ingår i: Analytical Chemistry. - Washington : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 70:23, s. 5002-5009
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A new procedure for the quantitation of C-21 ketosteroids using trifluoromethanesulfonic acid-catalyzed precolumn dansylation and coupled column liquid chromatographic separation, followed by postcolumn 1,1‘-oxalyldiimidazole peroxyoxalate chemiluminescence detection is presented. In the simultaneous optimization of chromatographic resolution and chemiluminescence intensity, a coupled column chromatographic system and a stopped-flow system were used. An eluent containing 20 mM phosphate buffer at pH 6.7 accomplished an efficient separation of 3α-hydroxy-5β-pregnan-20-one from a mixture containing 10 C-21 ketosteroids. Phosphate buffer also proved to be the most advantageous, among the six buffers tested, for sensitive detection. Experimental design and multivariate data analysis were used to characterize and optimize the postcolumn reaction chemistry in the chromatographic system. A valid full factorial design with excellent predictability showed that the flow rates for both 1,1‘-oxalyldiimidazole and hydrogen peroxide were the factors most strongly affecting the sensitivity of the system. The theoretical plate numbers were above 11 000 for all 10 dansylated ketosteroids. The 3σ detection limit estimated from 3α-hydroxy-5β-pregnan-20-one calibration curve data was 1.6 pmol (n = 4, 125 μL injected) and spiked serum containing 0−74 pmol of this compound showed overall recoveries of 73 ± 9% (n = 12). Quantitation of 3α-hydroxy-5β-pregnan-20-one was finally carried out on 45 serum samples and the results compared to those from a radioimmunoassay (RIA) method. The data acquired with the procedure described in this work compare well with the results from RIA, which confirms the reliability of the new analytical procedure.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

performance liquid chromatography
bile-acids
steroids
reagent
system

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Appelblad, Patri ...
Jonsson, Tobias
Bäckström, Torbj ...
Irgum, Knut
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Analytical Chemi ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy