SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Carlsson Charlotte)
 

Search: WFRF:(Carlsson Charlotte) > Test-retest reliabi...

Test-retest reliability of step counts with the ActivPAL™ device in common daily activities.

Dahlgren, Gunilla (author)
Umeå universitet,Institutionen för samhällsmedicin och rehabilitering
Carlsson, Daniel (author)
Umeå universitet,Sjukgymnastik
Moorhead, Anne (author)
Health and Rehabilitation Sciences Research Institute, School of Health Sciences, University of Ulster, Co. Antrim, Northern Ireland, United Kingdom
show more...
Häger-Ross, Charlotte (author)
Umeå universitet,Sjukgymnastik
McDonough, Suzanne M (author)
Health and Rehabilitation Sciences Research Institute, School of Health Sciences, University of Ulster, Co. Antrim, Northern Ireland, United Kingdom
show less...
 (creator_code:org_t)
Elsevier, 2010
2010
English.
In: Gait & Posture. - : Elsevier. - 0966-6362 .- 1879-2219. ; 32:3, s. 386-90
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The ActivPAL device is a well-established physical activity monitor for assessment of physical activity. AIM: To investigate test-retest reliability of step counts and establish minimal detectable changes (MDC) in step count to account for intra device error over time in various physical activities. METHODS: Healthy participants (n=24, age range, 19-28 years) performed activities on two occasions, 1 week apart, in a laboratory setting; self-paced floor walking, treadmill walking at three different speeds (3.2 km/h, 4.5 km/h and 4.5 km/h with incline), treadmill jogging (8.0 km/h), stair walking and cycling on an exercise bike at three speeds (45 rpm, 60 rpm and 75 rpm). Relative reliability was calculated using intraclass correlation coefficient (ICC) and Spearman correlation. Absolute reliability was assessed using standard error of measurement (SEM) and coefficient of repeatability (CR). RESULTS: The ActivPAL showed high to very high relative reliability for treadmill walking at all speeds and stair walking, while self-paced normal floor walking showed moderate reliability. The absolute reliability was the best for treadmill walking activities, slightly increased for self-paced walking, followed by stair walking and jogging. The use of activity monitors during cycling has been questioned and our results confirm a low absolute and relative reliability. MDC values varied according to the type of activity e.g. treadmill walking 4.5 km/h (10 steps), walking on the floor (45 steps). Data loss in this study (10-13%) was higher than previously reported. CONCLUSIONS: The ActivPAL is reliable for treadmill walking, jogging and self-paced walking. MCD varies according to the activity and should be considered when establishing true change over time.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Sjukgymnastik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Physiotherapy (hsv//eng)

Keyword

Accelerometer; Physical activity; Reliability; ActivPAL
sjukgymnastik
Physiotherapy

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Dahlgren, Gunill ...
Carlsson, Daniel
Moorhead, Anne
Häger-Ross, Char ...
McDonough, Suzan ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Health Sciences
and Physiotherapy
Articles in the publication
Gait & Posture
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view