SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Karlsson Mikael)
 

Sökning: WFRF:(Karlsson Mikael) > (2000-2004) > Electron beam colli...

  • Karlsson, M GUmeå universitet,Radiofysik (författare)

Electron beam collimation with focused and curved leaf end MLCs - Experimental verification of Monte Carlo optimized designs

  • Artikel/kapitelEngelska2002

Förlag, utgivningsår, omfång ...

  • 2002-03-25
  • Wiley,2002
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:umu-39942
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-39942URI
  • https://doi.org/10.1118/1.1464545DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • In general, electron beams, from conventional accelerators using applicators with lead alloy inserts are not suitable for advanced conformal radiation therapy. However, interesting electron treatments have been demonstrated on a few advanced accelerators. These accelerators have been equipped with helium filled treatment heads and computer controlled MLCs that produce clinically useful energy modulated electron beams or mixed photon electron beams in an automated sequence. This study analyzes the characteristics of different MLC designs, curved and focused leaf ends in helium filled treatment heads, with respect to their effect on electron beams. In addition, this study analyzes the effects that different treatment head designs have on the output factor due to collimator scattering and shielding of secondary sources during treatment. The investigation of the different treatment head designs was performed with the Monte Carlo package BEAM and was verified by experimental methods. The results show that the difference between curved leaf ends and focused ends is negligible in most practical cases. The results also show the importance of scattering foil optimization in the optimization of parameters such as penumbra. virtual source position, and in the reduction of the output variation. In all cases, the experimental data verifies the calculations. (C) 2002 American Association of Physicists in Medicine.

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Karlsson, MikaelUmeå universitet,Radiofysik(Swepub:umu)mika0003 (författare)
  • Umeå universitetRadiofysik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Medical physics (Lancaster): Wiley29:4, s. 631-6370094-2405

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Karlsson, M G
Karlsson, Mikael
Artiklar i publikationen
Medical physics ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy