SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1879 0887 OR L773:0167 8140
 

Sökning: L773:1879 0887 OR L773:0167 8140 > (1990-1994) > Matching of electro...

Matching of electron and photon beams with a multi-leaf collimator

Karlsson, Mikael (författare)
Umeå universitet,Radiofysik
Zackrisson, Björn (författare)
Umeå universitet,Onkologi
 (creator_code:org_t)
Elsevier BV, 1993
1993
Engelska.
Ingår i: Radiotherapy and Oncology. - : Elsevier BV. - 0167-8140 .- 1879-0887. ; 29:3, s. 317-326
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Multi-leaf collimators (MLCs) are offered as an accessory to many accelerators for radiation therapy. However, beam edges generated with these collimators are not as smooth as can be achieved with individually made blocks. The clinical drawbacks and benefits of this ripple were evaluated both for single field treatments and for combined adjacent fields of different beam qualities. In this investigation the MLC-collimated beams of the MM50 racetrack microtron were studied. The distance between the field edge and the 90% isodose was measured at the reference depth for four beam qualities (20 MV photons and 10, 20 and 50 MeV electrons). This distance was found to vary from approximately 6 mm for straight beam edges (i.e., all collimator leaves aligned) to approximately 2 mm from the tip of the leaves for a saw-tooth shaped beam edge. The over- and under-dosage in the joint between combined adjacent fields was found to be typically +/- 10% in small volumes. Improved clinical techniques using adjacent photon and electron fields with the same isocentre and source position (without moving the gantry) have been developed. For treatments of the breast, including the mammary chain, a uniform dose distribution was created with special attention given to the irradiation of the heart and lung outside the target volume. A method for head and neck treatments was optimised to give uniform dose distribution in the joint between the photon and electron fields and a method of treating the mediastinum, including the chest wall in front of the left lung, was analysed with respect to dose uniformity in the tumour and shielding of the lung.

Nyckelord

Multi-leaf indicator; Multi-leaf collimator; Radiation therapy; Racetrack microtron

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Karlsson, Mikael
Zackrisson, Björ ...
Artiklar i publikationen
Radiotherapy and ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy