SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Oddershede L. B.)
 

Sökning: WFRF:(Oddershede L. B.) > Optimizing active a...

Optimizing active and passive calibration of optical tweezers

Andersson, Magnus (författare)
Umeå universitet,Institutionen för fysik
Czerwinski, Fabian (författare)
The Niels Bohr Institute, University of Copenhagen, Denmark
Oddershede, L B (författare)
The Niels Bohr Institute, University of Copenhagen, Denmark
 (creator_code:org_t)
2011-03-04
2011
Engelska.
Ingår i: Journal of optics. - : IOP Publishing. - 0150-536X .- 2040-8978 .- 2040-8986. ; 13:4
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • To obtain quantitative information from optical trapping experiments it is essential to perform a precise force calibration. Therefore, sources of noise should be pinpointed and eliminated. Fourier analysis is routinely used to calibrate optical trapping assays because it is excellent for pinpointing high frequency noise. In addition, Allan variance analysis is particularly useful for quantifying low frequency noise and for predicting the optimal measurement time. We show how to use Allan variance in combination with Fourier analysis for optimal calibration and noise reduction in optical trapping assays. The methods are applied to passive assays, utilizing the thermal motion of a trapped particle, and to active assays where the bead is harmonically driven. The active method must be applied in assays where, for example, the viscoelastic properties of the medium or the size or shape of the trapped object are unknown. For measurement times shorter than the optimal calibration time the noise is larger in active than in the passive assays. For times equal to or longer than the optimal measurement time, though, the noise on passive and active assays is identical. As an example, we show how to quantify the influence on measurement noise of bead size and chamber geometry in active and passive assays.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Nyckelord

optical tweezers
allan variance
calibration
Physics
Fysik
fysik
Physics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Andersson, Magnu ...
Czerwinski, Fabi ...
Oddershede, L B
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
Artiklar i publikationen
Journal of optic ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy