SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Poelaert Jan)
 

Sökning: WFRF:(Poelaert Jan) > Left ventricular tw...

Left ventricular twist is load-dependent

A'roch, Roman, 1959- (författare)
Umeå universitet,Anestesiologi och intensivvård
Gustafsson, Ulf (författare)
Umeå universitet,Medicin
Poelaert, Jan (författare)
Dept of Anesthesiology and Perioperative Medicine, University hospital of Brussels. Belgium
visa fler...
Johansson, Göran (författare)
Umeå universitet,Anestesiologi och intensivvård
Haney, Michael (författare)
Umeå universitet,Anestesiologi och intensivvård
visa färre...
 (creator_code:org_t)
Engelska.
  • Annan publikation (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Background: Left ventricular rotation and twist can be assessed noninvasively by speckle tracking echocardiography. We sought to characterize the effects of acute load change and change in inotropic state on rotation parameters as a measure of LV contractility. Methods: Seven anesthetised juvenile pigs were studied, using direct measurement of left ventricular (LV) pressure and volume and simultaneous transthoracic echocardiography. Transient inflation of an inferior vena cava balloon catheter (IVCBO) produced controlled load reduction.  First and last beats in the sequence of eight were analysed with speckle tracking (STE) during the load alteration and analysed for change in rotation/twist during controlled load alteration at same contractile status.  Two pharmacological inotropic interventions were also included to examine the same hypothesis in additionally conditions of increased and decreased myocardial contractility in each animal. Results: The IVCBO load change compared for first to last beat resulted in LV twist increase (11.67° ±2.65° vs. 16.17° ±3.56° respectively, p < 0.004) during the load alteration and under adrenaline stimulation LV twist increase 12.56° ±5.1° vs. 16.57° ±4.6° (p < 0.013), and though increased, didn’t reach significance in nega­tive inotropic condition.  Untwisting rate increased significantly at baseline from    -41.7°/sec ±41.6°/sec vs. -122.6°/sec ±55.8°/sec (P < 0.039) and under adrenaline stimulation untwisting rate increased  (-55.3°/sec ±3.8°/sec vs.  -111.4°/sec ±24.0°/sec (p<0.05), but did not systematically changed in negative inotropic condition. Conclusions: Peak systolic LV twist and peak early diastolic untwisting rate are load dependent.  Changes in LV load should be considered when interpreting  LV rotation/ twist.

Nyckelord

echocardiography
ventricular function
rotation
torsion
load

Publikations- och innehållstyp

vet (ämneskategori)
ovr (ämneskategori)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy