SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Hauksson Jón)
 

Sökning: WFRF:(Hauksson Jón) > (2010-2014) > Contributions to qu...

Contributions to quantitative dynamic contrast-enhanced MRI

Garpebring, Anders, 1980- (författare)
Umeå universitet,Radiofysik
Karlsson, Mikael, Professor (preses)
Umeå universitet,Radiofysik
Wirestam, Ronnie, Professor (preses)
Lunds universitet, Medicinsk strålningsfysik
visa fler...
Östlund, Nils, Phd (preses)
Umeå universitet,Radiofysik
Hauksson, Jón, Phd (preses)
Umeå universitet,Radiofysik
Sourbron, Steven, Phd (opponent)
University of Leeds, Division of Medical Physics
visa färre...
 (creator_code:org_t)
ISBN 9789174593136
Umeå : Umeå Universitet, 2011
Engelska 108 s.
Serie: Umeå University medical dissertations, 0346-6612 ; 1457
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Background: Dynamic contrast-enhanced MRI (DCE-MRI) has the potential to produce images of physiological quantities such as blood flow, blood vessel volume fraction, and blood vessel permeability. Such information is highly valuable, e.g., in oncology. The focus of this work was to improve the quantitative aspects of DCE-MRI in terms of better understanding of error sources and their effect on estimated physiological quantities. Methods: Firstly, a novel parameter estimation algorithm was developed to overcome a problem with sensitivity to the initial guess in parameter estimation with a specific pharmacokinetic model. Secondly, the accuracy of the arterial input function (AIF), i.e., the estimated arterial blood contrast agent concentration, was evaluated in a phantom environment for a standard magnitude-based AIF method commonly used in vivo. The accuracy was also evaluated in vivo for a phase-based method that has previously shown very promising results in phantoms and in animal studies. Finally, a method was developed for estimation of uncertainties in the estimated physiological quantities. Results: The new parameter estimation algorithm enabled significantly faster parameter estimation, thus making it more feasible to obtain blood flow and permeability maps from a DCE-MRI study. The evaluation of the AIF measurements revealed that inflow effects and non-ideal radiofrequency spoiling seriously degrade magnitude-based AIFs and that proper slice placement and improved signal models can reduce this effect. It was also shown that phase-based AIFs can be a feasible alternative provided that the observed difficulties in quantifying low concentrations can be resolved. The uncertainty estimation method was able to accurately quantify how a variety of different errors propagate to uncertainty in the estimated physiological quantities. Conclusion: This work contributes to a better understanding of parameter estimation and AIF quantification in DCE-MRI. The proposed uncertainty estimation method can be used to efficiently calculate uncertainties in the parametric maps obtained in DCE-MRI.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

Dynamic contrast-enhanced MRI
quantitative imaging
parameter estimation
uncertainty estimation
arterial input function
radiofysik
radiation physics

Publikations- och innehållstyp

vet (ämneskategori)
dok (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy