SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Marklund Stellan)
 

Sökning: WFRF:(Marklund Stellan) > (2010-2014) > Accurate sampling o...

Accurate sampling of PCDD/F in high temperature flue-gas using cooled sampling probes

Duong Phan, Ngoc Chau (författare)
Umeå universitet,Kemiska institutionen
Weidemann, Eva, 1982- (författare)
Umeå universitet,Kemiska institutionen
Lundin, Lisa, 1976- (författare)
Umeå universitet,Kemiska institutionen
visa fler...
Marklund, Stellan, 1949- (författare)
Umeå universitet,Kemiska institutionen
Jansson, Stina (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Skogens biomaterial och teknologi,Department of Forest Biomaterials and Technology,Unit of Biomass Technology and Chemistry
visa färre...
 (creator_code:org_t)
 
Elsevier, 2012
2012
Engelska.
Ingår i: Chemosphere. - : Elsevier. - 0045-6535 .- 1879-1298. ; 88:7, s. 832-836
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In a laboratory-scale combustion reactor, flue-gas samples were collected at two temperatures in the post-combustion zone, 700 °C and 400 °C, using two different water-cooled sampling probes. The probes were the cooled probe described in the European Standard method EN-1948:1, referred to as the original probe, and a modified probe that contained a salt/ice mixture to assist the cooling, referred to as the sub-zero probe. To determine the efficiency of the cooling probes, internal temperature measurements were recorded at 5 cm intervals inside the probes. Flue-gas samples were analyzed for polychlorinated dibenzo-p-dioxin and dibenzofurans (PCDD/Fs). Samples collected at 700 °C using the original cooling probe showed higher concentrations of PCDD/Fs compared to samples collected using the sub-zero probe. No significant differences were observed between samples collected at 400 °C. The results indicated that artifact formation of PCDD/Fs readily occurs during flue-gas sampling at high temperatures if the cooling within the probe is insufficient, as found for the original probe at 700 °C. It was also shown that this problem could be alleviated by using probes with an enhanced cooling capacity, such as the sub-zero probe.Although this may not affect samples collected for regulatory purposes in exit gases, it is of great importance for research conducted in the high-temperature region of the post-combustion zone. 

Ämnesord

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)
NATURVETENSKAP  -- Geovetenskap och miljövetenskap -- Miljövetenskap (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences -- Environmental Sciences (hsv//eng)

Nyckelord

Polychlorinated dibenzo-p-dioxins
Polychlorinated dibenzofurans
Quenching
Sub-zero cooling probe
Waste combustion

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng