SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-55008"
 

Sökning: id:"swepub:oai:DiVA.org:umu-55008" > A content validated...

  • Bölenius, KarinUmeå universitet,Institutionen för omvårdnad (författare)

A content validated questionnaire for assessment of self reported venous blood sampling practices

  • Artikel/kapitelEngelska2012

Förlag, utgivningsår, omfång ...

  • 2012-01-19
  • Springer Science and Business Media LLC,2012
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:umu-55008
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-55008URI
  • https://doi.org/10.1186/1756-0500-5-39DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • BACKGROUND: Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability.FINDINGS: We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria.CONCLUSIONS: The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Brulin, ChristineUmeå universitet,Institutionen för omvårdnad(Swepub:umu)chbr0002 (författare)
  • Grankvist, KjellUmeå universitet,Klinisk kemi(Swepub:umu)kjgr0002 (författare)
  • Lindkvist, MarieUmeå universitet,Epidemiologi och global hälsa(Swepub:umu)mali0004 (författare)
  • Söderberg, JohanUmeå universitet,Klinisk kemi(Swepub:umu)jansog99 (författare)
  • Umeå universitetInstitutionen för omvårdnad (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:BMC Research Notes: Springer Science and Business Media LLC5, s. 39-1756-0500

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy