A high blood level in the air trap reduces microemboli during hemodialysis

Forsberg, Ulf (författare)
Umeå universitet,Medicin
Jonsson, Per (författare)
Umeå universitet,Medicin
Stegmayr, Christofer (författare)
Umeå universitet,Medicin
visa fler...
Stegmayr, Bernd (författare)
Umeå universitet,Medicin
visa färre...
 (creator_code:org_t)
2012-02-23
2012
Engelska.
Ingår i: Artificial Organs. - : Wiley. - 0160-564X .- 1525-1594. ; 36:6, s. 525-529
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Previous studies have demonstrated the presence of air microemboli in the dialysis circuit and in the venous circulation of the patients during hemodialysis. In vitro studies indicate that a high blood level in the venous air trap reduces the extent of microbubble formation. The purpose of this study was to examine whether air microbubbles can be detected in the patient's access and if so, whether the degree of microbubble formation can be altered by changing the blood level in the venous air trap. This was a randomized, double-blinded, interventional study of 20 chronic hemodialysis patients. The patients were assigned to hemodialysis with either an elevated or a low blood level in the air trap. The investigator and the patient were blinded to the settings. The numbers of microbubbles were measured at the site of the arteriovenous (AV) access for 2 min with the aid of an ultrasonic Doppler device. The blood level in the air trap was then altered to the opposite setting and a new measurement was carried out after an equilibration period of 30 min. Median (range) for the number of microbubbles measured with the high air trap level and the low air trap level in AV access was 2.5 (0-80) compared with 17.5 (0-77), respectively (P = 0.044). The degree of microbubble formation in hemodialysis patients with AV access was reduced significantly if the blood level in the air trap was kept high. The exposure of potentially harmful air microbubbles was thereby significantly reduced. This measure can be performed with no additional healthcare cost.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Hematologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Hematology (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Forsberg, Ulf
Jonsson, Per
Stegmayr, Christ ...
Stegmayr, Bernd
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Hematologi
Artiklar i publikationen
Artificial Organ ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy