SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-57253"
 

Sökning: id:"swepub:oai:DiVA.org:umu-57253" > Imaging of parastom...

  • Gurmu, ADepartment of Surgery, CLINTEC, Karolinska Institute at the Karolinska University Hospital, Huddinge, Stockholm, Sweden (författare)

Imaging of parastomal hernia using three-dimensional intrastomal ultrasonography

  • Artikel/kapitelEngelska2011

Förlag, utgivningsår, omfång ...

  • 2011-04-20
  • Oxford University Press (OUP),2011
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:umu-57253
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-57253URI
  • https://doi.org/10.1002/bjs.7505DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:122732618URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • BACKGROUND: Parastomal hernia is common in patients with a permanent stoma. At present there is no standard method for imaging a parastomal hernia. The aim of this study was to investigate the value of three-dimensional intrastomal ultrasonography in differentiating between a parastomal hernia and a bulge.METHODS: Twenty patients were divided into four groups according to ultrasonography setting and probe cover. All patients were tested using three different ultrasound probe frequencies (9, 13 and 16 MHz). The intrastomal examination was performed during provocation in both the supine and upright positions, with a protector or water-containing balloon surrounding the probe.RESULTS: The sharpest images were obtained using the rectal setting with a water-containing balloon surrounding the probe at 9 MHz in supine and erect positions, for evaluation of both fascia and muscle; in some instances even implanted mesh was detectable. When switched to render mode, the pictures improved in sharpness and it was easier to identify anatomical landmarks.CONCLUSION: Intrastomal ultrasonography using the rectal setting and a frequency of 9 MHz is a feasible method for imaging a parastomal hernia and differentiating it from an abdominal bulge. The image quality improves when render mode is used.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Gunnarsson, Ulf,1967-Karolinska Institutet(Swepub:umu)ulgu0014 (författare)
  • Strigård, Karin,1958-Karolinska Institutet(Swepub:umu)kast0065 (författare)
  • Karolinska InstitutetDepartment of Surgery, CLINTEC, Karolinska Institute at the Karolinska University Hospital, Huddinge, Stockholm, Sweden (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:British Journal of Surgery: Oxford University Press (OUP)98:7, s. 1026-90007-13231365-2168

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Gurmu, A
Gunnarsson, Ulf, ...
Strigård, Karin, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
British Journal ...
Av lärosätet
Umeå universitet
Karolinska Institutet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy