Assessment of abdominal muscle function using the Biodex System-4. Validity and reliability in healthy volunteers and patients with giant ventral hernia

  • Artikel/kapitelEngelska2011

Förlag, utgivningsår, omfång ...

  • 2011-03-05
  • Paris :Springer,2011
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:umu-57255
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-57255URI
  • https://doi.org/10.1007/s10029-011-0805-1DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:122988878URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • BACKGROUND: The decrease in recurrence rates in ventral hernia surgery have led to a redirection of focus towards other important patient-related endpoints. One such endpoint is abdominal wall function. The aim of the present study was to evaluate the reliability and external validity of abdominal wall strength measurement using the Biodex System-4 with a back abdomen unit.MATERIAL AND METHOD: Ten healthy volunteers and ten patients with ventral hernias exceeding 10 cm were recruited. Test-retest reliability, both with and without girdle, was evaluated by comparison of measurements at two test occasions 1 week apart. Reliability was calculated by the interclass correlation coefficients (ICC) method. Validity was evaluated by correlation with the well-established International Physical Activity Questionnaire (IPAQ) and a self-assessment of abdominal wall strength.RESULTS: One person in the healthy group was excluded after the first test due to neck problems following minor trauma. The reliability was excellent (>0.75), with ICC values between 0.92 and 0.97 for the different modalities tested. No differences were seen between testing with and without a girdle. Validity was also excellent both when calculated as correlation to self-assessment of abdominal wall strength, and to IPAQ, giving Kendall tau values of 0.51 and 0.47, respectively, and corresponding P values of 0.002 and 0.004.CONCLUSION: Measurement of abdominal muscle function using the Biodex System-4 is a reliable and valid method to assess this important patient-related endpoint. Further investigations will be made to explore the potential of this technique in the evaluation of the results of ventral hernia surgery, and to compare muscle function after different abdominal wall reconstruction techniques.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Johansson, MDepartment of Physiotherapy, Karolinska Institutet, Karolinska University Hospital, Huddinge, Stockholm, Sweden (författare)
  • Strigård, Karin,1958-Karolinska Institutet(Swepub:umu)kast0065 (författare)
  • Karolinska InstitutetDepartment of Physiotherapy, Karolinska Institutet, Karolinska University Hospital, Huddinge, Stockholm, Sweden (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:HerniaParis : Springer15:4, s. 417-4211265-49061248-9204

Internetlänk

Hitta via bibliotek

  • Hernia (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Gunnarsson, Ulf, ...
Johansson, M
Strigård, Karin, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
Hernia
Av lärosätet
Umeå universitet
Karolinska Institutet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy