SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0968 5243
 

Sökning: L773:0968 5243 > (2010-2014) > Evaluation of an at...

Evaluation of an attenuation correction method for PET/MR imaging of the head based on substitute CT images

Larsson, Anne (författare)
Umeå universitet,Radiofysik
Johansson, Adam (författare)
Umeå universitet,Radiofysik
Axelsson, Jan (författare)
Umeå universitet,Radiofysik
visa fler...
Nyholm, Tufve (författare)
Umeå universitet,Radiofysik
Asklund, Thomas (författare)
Umeå universitet,Radiofysik
Riklund, Katrine (författare)
Umeå universitet,Diagnostisk radiologi
Karlsson, Mikael (författare)
Umeå universitet,Radiofysik
visa färre...
 (creator_code:org_t)
2012-09-07
2013
Engelska.
Ingår i: Magnetic Resonance Materials in Physics, Biology and Medicine. - : Springer Science and Business Media LLC. - 0968-5243 .- 1352-8661. ; 26:1, s. 127-136
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this study was to evaluate MR-based attenuation correction of PET emission data of the head, based on a previously described technique that calculates substitute CT (sCT) images from a set of MR images. Images from eight patients, examined with F-18-FLT PET/CT and MRI, were included. sCT images were calculated and co-registered to the corresponding CT images, and transferred to the PET/CT scanner for reconstruction. The new reconstructions were then compared with the originals. The effect of replacing bone with soft tissue in the sCT-images was also evaluated. The average relative difference between the sCT-corrected PET images and the CT-corrected PET images was 1.6 % for the head and 1.9 % for the brain. The average standard deviations of the relative differences within the head were relatively high, at 13.2 %, primarily because of large differences in the nasal septa region. For the brain, the average standard deviation was lower, 4.1 %. The global average difference in the head when replacing bone with soft tissue was 11 %. The method presented here has a high rate of accuracy, but high-precision quantitative imaging of the nasal septa region is not possible at the moment.

Nyckelord

PET/MR
Attenuation correction
Substitute CT
F-18-FLT
UTE

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy