SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Behrens Anders)
 

Search: WFRF:(Behrens Anders) > Are intracranial pr...

Are intracranial pressure wave amplitudes measurable through lumbar puncture?

Behrens, Anders (author)
Umeå universitet,Klinisk neurovetenskap
Lenfeldt, Niklas (author)
Umeå universitet,Klinisk neurovetenskap
Qvarlander, Sara (author)
Umeå universitet,Radiofysik
show more...
Koskinen, Lars-Owe (author)
Umeå universitet,Klinisk neurovetenskap
Malm, Jan (author)
Umeå universitet,Klinisk neurovetenskap
Eklund, Anders (author)
Umeå universitet,Klinisk neurovetenskap
show less...
 (creator_code:org_t)
2012-07-11
2013
English.
In: Acta Neurologica Scandinavica. - : Hindawi Limited. - 0001-6314 .- 1600-0404. ; 127:4, s. 233-241
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  •  Objective The aim of this study was to investigate whether pulsations measured in the brain correspond to those measured in lumbar space, and subsequently whether lumbar punctures could replace invasive recordings. Methods In ten patients with normal pressure hydrocephalus, simultaneous recordings of the intracranial pressure (ICP; intraparenchymal) and lumbar pressure (LP; cerebrospinal fluid pressure) were performed. During registration, pressure was altered between resting pressure and 45mmHg using an infusion test. Data were analyzed regarding pulsations (i.e., amplitudes). Also, the pressure sensors were compared in a bench test. Results The correlation between intracranial and lumbar amplitudes was 0.98. At resting pressure, and moderately elevated ICP, intracranial pulse amplitudes exceeded that of lumbar space with about 0.9mmHg. At the highest ICP, the difference changed to 0.2mmHg. The bench test showed that the agreement of sensor readings was good at resting pressure, but reduced at higher amplitudes. Conclusions Compared to intracranial registrations, amplitudes measured through lumbar puncture were slightly attenuated. The bench test showed that differences were not attributable to dissimilarities of the sensor systems. A lumbar pressure amplitude measurement is an alternative to ICP recording, but the thresholds for what should be interpreted as elevated amplitudes need to be adjusted.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)

Keyword

intracranial pressure
spinal puncture
cerebrospinal fluid pressure
hydrocephalus
normal pressure
pulse pressure waves

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Behrens, Anders
Lenfeldt, Niklas
Qvarlander, Sara
Koskinen, Lars-O ...
Malm, Jan
Eklund, Anders
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Neurology
Articles in the publication
Acta Neurologica ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view