SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Jahnson Staffan)
 

Sökning: WFRF:(Jahnson Staffan) > A novel model of ar...

A novel model of artificial intelligence based automated image analysis of CT urography to identify bladder cancer in patients investigated for macroscopic hematuria

Abuhasanein, Suleiman (författare)
Sahlgrenska Academy
Edenbrandt, Lars (författare)
Sahlgrenska University Hospital
Enqvist, Olof (författare)
Chalmers University of Technology
visa fler...
Jahnson, Staffan (författare)
Linköping University
Leonhardt, Henrik (författare)
Sahlgrenska Academy
Trägårdh, Elin (författare)
Lund University,Lunds universitet,Institutionen för translationell medicin,Medicinska fakulteten,Klinisk fysiologi och nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,WCMM- Wallenberg center för molekylär medicinsk forskning,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Department of Translational Medicine,Faculty of Medicine,Clinical Physiology and Nuclear Medicine, Malmö,Lund University Research Groups,WCMM-Wallenberg Centre for Molecular Medicine,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital
Ulén, Johannes (författare)
Eigenvision AB
Kjölhede, Henrik (författare)
Sahlgrenska Academy
visa färre...
 (creator_code:org_t)
2024
2024
Engelska 8 s.
Ingår i: Scandinavian Journal of Urology. - 2168-1813. ; 59, s. 90-97
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVE: To evaluate whether artificial intelligence (AI) based automatic image analysis utilising convolutional neural networks (CNNs) can be used to evaluate computed tomography urography (CTU) for the presence of urinary bladder cancer (UBC) in patients with macroscopic hematuria. METHODS: Our study included patients who had undergone evaluation for macroscopic hematuria. A CNN-based AI model was trained and validated on the CTUs included in the study on a dedicated research platform (Recomia.org). Sensitivity and specificity were calculated to assess the performance of the AI model. Cystoscopy findings were used as the reference method. RESULTS: The training cohort comprised a total of 530 patients. Following the optimisation process, we developed the last version of our AI model. Subsequently, we utilised the model in the validation cohort which included an additional 400 patients (including 239 patients with UBC). The AI model had a sensitivity of 0.83 (95% confidence intervals [CI], 0.76-0.89), specificity of 0.76 (95% CI 0.67-0.84), and a negative predictive value (NPV) of 0.97 (95% CI 0.95-0.98). The majority of tumours in the false negative group (n = 24) were solitary (67%) and smaller than 1 cm (50%), with the majority of patients having cTaG1-2 (71%). CONCLUSIONS: We developed and tested an AI model for automatic image analysis of CTUs to detect UBC in patients with macroscopic hematuria. This model showed promising results with a high detection rate and excessive NPV. Further developments could lead to a decreased need for invasive investigations and prioritising patients with serious tumours.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy