SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Elsayed Moneim)
 

Sökning: WFRF:(Elsayed Moneim) > (2000) > Optimisation of ope...

  • Elsayed, MoneimUmeå universitet,Kemiska institutionen (författare)

Optimisation of operating parameters for simultaneous multi-element determination of antimony, arsenic, bismuth and selenium by hydride generation, graphite atomiser sequestration atomic absorption spectrometry

  • Artikel/kapitelEngelska2000

Förlag, utgivningsår, omfång ...

  • 2000
  • Royal Society of Chemistry (RSC),2000
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:umu-8533
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-8533URI
  • https://doi.org/10.1039/a908635hDOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Hydride generation, sequestration in graphite tubes and simultaneous multi-element measurement by atomic absorption spectrometry were used for determination of Sb(V), Bi(III), Se(IV), As(III) and As(V) in Millipore or brackish water by a method based on batchwise addition of the samples to a reaction vessel. As the reducing agent, NaBH4 was added at a controlled flow rate. A statistical programme, Modde 4.0, capable of multivariate optimisation of working parameters for the multi-element determination, was used to optimise the concentrations of HCl, the amount of NaBH4, purge gas flow rates, the graphite atomiser's deposition temperature, as well as the temperature of the reaction vessel.In general, the concentrations of HCl and the amount of NaBH4 had the greatest impact on the response and several of the working parameters showed interactions. For highest sensitivity different parameters had to be used for the two matrices. Optimum parameter settings in Millipore and brackish water were: concentration of HCl 2.1 and 2.7 mol l(-1), respectively; 2% NaBH4 addition during 120 s (4 ml) or 84 s (2.8 ml), respectively; Ar purge gas flow rate 150 ml min(-1) in both matrices; reaction vessel temperature 16 and 0 degrees C, respectively; and a deposition temperature of 600 and 150 degrees C, respectively. The detection limits were restricted by variations in the blank absorbance. For 2 ml of sample the detection limits in brackish water were 17, 14, 25 and 140 ng l(-1) for As, Se(IV), Bi and Sb, respectively.

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Björn, ErikUmeå universitet,Kemiska institutionen(Swepub:umu)erkbjn97 (författare)
  • Frech, WolfgangUmeå universitet,Kemiska institutionen (författare)
  • Umeå universitetKemiska institutionen (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY: Royal Society of Chemistry (RSC)15:6, s. 697-703
  • Ingår i:J. Anal. At. Spectrom.: Royal Society of Chemistry (RSC)15:6, s. 697-7030267-94771364-5544

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Elsayed, Moneim
Björn, Erik
Frech, Wolfgang
Artiklar i publikationen
J. Anal. At. Spe ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy