SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:umu-8533"
 

Search: id:"swepub:oai:DiVA.org:umu-8533" > Optimisation of ope...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Elsayed, MoneimUmeå universitet,Kemiska institutionen (author)

Optimisation of operating parameters for simultaneous multi-element determination of antimony, arsenic, bismuth and selenium by hydride generation, graphite atomiser sequestration atomic absorption spectrometry

  • Article/chapterEnglish2000

Publisher, publication year, extent ...

  • 2000
  • Royal Society of Chemistry (RSC),2000
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:umu-8533
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-8533URI
  • https://doi.org/10.1039/a908635hDOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Hydride generation, sequestration in graphite tubes and simultaneous multi-element measurement by atomic absorption spectrometry were used for determination of Sb(V), Bi(III), Se(IV), As(III) and As(V) in Millipore or brackish water by a method based on batchwise addition of the samples to a reaction vessel. As the reducing agent, NaBH4 was added at a controlled flow rate. A statistical programme, Modde 4.0, capable of multivariate optimisation of working parameters for the multi-element determination, was used to optimise the concentrations of HCl, the amount of NaBH4, purge gas flow rates, the graphite atomiser's deposition temperature, as well as the temperature of the reaction vessel.In general, the concentrations of HCl and the amount of NaBH4 had the greatest impact on the response and several of the working parameters showed interactions. For highest sensitivity different parameters had to be used for the two matrices. Optimum parameter settings in Millipore and brackish water were: concentration of HCl 2.1 and 2.7 mol l(-1), respectively; 2% NaBH4 addition during 120 s (4 ml) or 84 s (2.8 ml), respectively; Ar purge gas flow rate 150 ml min(-1) in both matrices; reaction vessel temperature 16 and 0 degrees C, respectively; and a deposition temperature of 600 and 150 degrees C, respectively. The detection limits were restricted by variations in the blank absorbance. For 2 ml of sample the detection limits in brackish water were 17, 14, 25 and 140 ng l(-1) for As, Se(IV), Bi and Sb, respectively.

Added entries (persons, corporate bodies, meetings, titles ...)

  • Björn, ErikUmeå universitet,Kemiska institutionen(Swepub:umu)erkbjn97 (author)
  • Frech, WolfgangUmeå universitet,Kemiska institutionen (author)
  • Umeå universitetKemiska institutionen (creator_code:org_t)

Related titles

  • In:JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY: Royal Society of Chemistry (RSC)15:6, s. 697-703
  • In:J. Anal. At. Spectrom.: Royal Society of Chemistry (RSC)15:6, s. 697-7030267-94771364-5544

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Elsayed, Moneim
Björn, Erik
Frech, Wolfgang
Articles in the publication
J. Anal. At. Spe ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view