The circular stapling device as a risk factor for anastomotic leakage.

Folkesson, J (author)
Uppsala universitet,Institutionen för kirurgiska vetenskaper,Gastrointestinal Surgery
Nilsson, J (author)
Påhlman, L (author)
Uppsala universitet,Institutionen för kirurgiska vetenskaper,Gastrointestinal Surgery
show more...
Glimelius, B (author)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
Gunnarsson, Ulf, 1967- (author)
Uppsala universitet,Institutionen för kirurgiska vetenskaper,Gastrointestinal Surgery
show less...
 (creator_code:org_t)
Wiley, 2004
2004
English.
In: Colorectal Disease. - : Wiley. - 1462-8910 .- 1463-1318. ; 6:4, s. 275-9
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • AIM: To investigate the relation between the type of circular stapler and anastomotic leak in rectal cancer surgery.BACKGROUND: During the past decades results from rectal cancer surgery have improved considerably regarding risk of local recurrence and survival. Two main paradigm changes are considered to be the cause for this: the introduction of total mesorectal excision (TME) and the increasing use of radiotherapy. However, rectal cancer surgery is associated with an unacceptably high frequency of complications of which anastomotic leak is one of the most severe ones. The hypothesis was raised that the choice of stapler influenced the leakage rates.METHODS: A questionnaire was sent to all departments of surgery (n = 66) performing rectal cancer surgery in Sweden to determine the choice of circular stapler when performing anterior resection for rectal cancer. These data were linked to the Swedish Rectal Cancer Registry for the period 1995-99.RESULTS: A total of 3316 patients had an anterior resection. The choice of circular stapling device was determined in 70% of the cases. When stapler A was used, the leakage rate was 11% whereas it was 7% when stapler B was used (P = 0.0039). In the cases where it was impossible to determine which stapler had been used the leakage rate was 8%.CONCLUSION: Quality control is an important part of medicine and the present study suggests that it also must include surgical instruments. A prospective randomised study is needed to confirm the results.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Gastroenterologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Gastroenterology and Hepatology (hsv//eng)

Keyword

Adult
Aged
80 and over
Anastomosis
Surgical/instrumentation
Colectomy/adverse effects/*instrumentation
Female
Humans
Male
Rectal Neoplasms/*surgery
*Registries
Quality of Health Care
Middle Aged
Retrospective Studies
Surgical Staplers/*adverse effects
Surgical Wound Dehiscence/*etiology
Sweden

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Folkesson, J
Nilsson, J
Påhlman, L
Glimelius, B
Gunnarsson, Ulf, ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Surgery
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Gastroenterology ...
Articles in the publication
Colorectal Disea ...
By the university
Umeå University
Uppsala University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view