SwePub
Sök i LIBRIS databas

  Extended search

L773:0740 3224
 

Search: L773:0740 3224 > Doppler broadened N...

  • Ehlers, Patrick,1981-Umeå universitet,Institutionen för fysik,Laser physics group (author)

Doppler broadened NICE-OHMS beyond the triplet formalism : assessment of optimum modulation index

  • Article/chapterEnglish2014

Publisher, publication year, extent ...

  • Optical Society of America,2014
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:umu-91852
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-91852URI
  • https://doi.org/10.1364/JOSAB.31.001499DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Ingår i Patrick Ehlers doktorsavhandling som delarbete nr XI med titeln: NICE-OHMS beyond the triplet formalism: assessment of the optimum modulation index.
  • The dependence of Doppler broadened noise-immune cavity-enhanced optical heterodyne molecular spectrometry (NICE-OHMS) on the modulation index, beta, has been investigated experimentally on C2H2 and CO2, both in the absence and the presence of optical saturation. It is shown that the maximum signals are obtained for beta that produce more than one pair of sidebands: in the Doppler limit and for the prevailing conditions (unsaturated transition and the pertinent modulation frequency and Doppler widths) around 1 and 1.4 for the dispersion and absorption detection phases, respectively. The results verify predictions given in an accompanying work. It is also shown that there is no substantial broadening of the NICE-OHMS signal for beta < 1. The use of beta of unity has yielded a Db-NICE-OHMS detection sensitivity of 4.9 x 10(-12) cm(-1) Hz(-1/2), which is the lowest (best) value so far achieved for NICE-OHMS based on a tunable laser. The number of sidebands that needs to be included in fits of the line-shape function to obtain good accuracy has been assessed. It is concluded that it is enough to consider three pairs of sidebands whenever the systematic errors in a concentration assessment should be below 1% when beta < 2 are used and <1 parts per thousand for beta < 1.5.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Wang, JunyangUmeå universitet,Institutionen för fysik(Swepub:umu)juwa0004 (author)
  • Silander, Isak,1980-Umeå universitet,Institutionen för fysik(Swepub:umu)issi0002 (author)
  • Axner, Ove,1957-Umeå universitet,Institutionen för fysik(Swepub:umu)ovax0001 (author)
  • Umeå universitetInstitutionen för fysik (creator_code:org_t)

Related titles

  • In:Journal of the Optical Society of America. B, Optical physics: Optical Society of America31:7, s. 1499-15070740-32241520-8540

Internet link

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view