SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Axner Ove 1957 )
 

Search: WFRF:(Axner Ove 1957 ) > Noise-immune cavity...

Noise-immune cavity-enhanced analytical atomic spectrometry — NICE-AAS : a technique for detection of elements down to zeptogram amounts

Axner, Ove, 1957- (author)
Umeå universitet,Institutionen för fysik
Ehlers, Patrick, 1981- (author)
Umeå universitet,Institutionen för fysik,Laser physics group
Hausmaninger, Thomas, 1987- (author)
Umeå universitet,Institutionen för fysik
show more...
Silander, Isak, 1980- (author)
Umeå universitet,Institutionen för fysik
Ma, Weiguang, 1976- (author)
Umeå universitet,Institutionen för fysik
show less...
 (creator_code:org_t)
Elsevier, 2014
2014
English.
In: Spectrochimica Acta Part B - Atomic Spectroscopy. - : Elsevier. - 0584-8547 .- 1873-3565. ; 100, s. 211-235
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS) is a powerful technique for detection of molecular compounds in gas phase that is based on a combination of two important concepts: frequency modulation spectroscopy (FMS) for reduction of noise, and cavity enhancement, for prolongation of the interaction length between the light and the sample. Due to its unique properties, it has demonstrated unparalleled detection sensitivity when it comes to detection of molecular constituents in the gas phase. However, despite these, it has so far not been used for detection of atoms, i.e. for elemental analysis. The present work presents an assessment of the expected performance of Doppler-broadened (Db) NICE-OHMS for analytical atomic spectrometry, then referred to as noise-immune cavity-enhanced analytical atomic spectrometry (NICE-AAS). After a description of the basic principles of Db-NICE-OHMS, the modulation and detection conditions for optimum performance are identified. Based on a previous demonstrated detection sensitivity of Db-NICE-OHMS of 5×10−12 cm−1 Hz−1∕2 (corresponding to a single-pass absorbance of 7×10−11 over 10 s), the expected limits of detection (LODs) of Hg and Na by NICE-AAS are estimated. Hg is assumed to be detected in gas phase directly while Na is considered to be atomized in a graphite furnace (GF) prior to detection. It is shown that in the absence of spectral interferences, contaminated sample compartments, and optical saturation, it should be feasible to detect Hg down to 10 zg/cm3 (10 fg/m3 or 10-5 ng/m3), which corresponds to 25 atoms/cm3, and Na down to 0.5 zg (zg = zeptogram = 10-21 g), representing 50 zg/mL (parts-per-sextillion, pps, 1:1021) in liquid solution (assuming a sample of 10 µL) or solely 15 atoms injected into the GF, respectively. These LODs are several orders of magnitude lower (better) than any previous laser-based absorption technique previously has demonstrated under atmospheric pressure conditions. It is prophesied that NICE-AAS could provide such high detection sensitivity that the instrumentation should not, by itself, be the limiting factor of an assessment of elemental abundance; the accuracy of an assessment would then instead be limited by concomitant species, e.g. originating from the handling procedures of the sample or the environment.

Subject headings

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Keyword

Noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS)
Frequency modulation spectroscopy (FMS)
Cavity enhanced (CE) spectroscopy
Ultra-trace element detection
Individual atom detection
fysik
Physics

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view