SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Beckman Per)
 

Sökning: WFRF:(Beckman Per) > Increased corneal h...

Increased corneal hysteresis after corneal collagen crosslinking : a study based on applanation resonance technology

Beckman Rehnman, Jeannette (författare)
Umeå universitet,Oftalmiatrik
Behndig, Anders (författare)
Umeå universitet,Oftalmiatrik
Hallberg, Per (författare)
Umeå universitet,Institutionen för strålningsvetenskaper
visa fler...
Lindén, Christina (författare)
Umeå universitet,Oftalmiatrik
visa färre...
 (creator_code:org_t)
American Medical Association, 2014
2014
Engelska.
Ingår i: JAMA ophthalmology. - : American Medical Association. - 2168-6165 .- 2168-6173. ; 132:12, s. 1426-1432
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Importance: A reliable tool for quantification of the biomechanical status of the cornea in conjunction with corneal collagen crosslinking (CXL) treatment is needed.Objective: To quantify the biomechanical effects of CXL in vivo.Design, Setting, and Participants: A prospective, open, case-control study was conducted at the Department of Ophthalmology, Umeå University, Umeå, Sweden. Participants included 28 patients (29 eyes) aged 18 to 28 years with progressive keratoconus and corresponding age- and sex-matched healthy individuals serving as controls. All participants were monitored during a 6-month period between October 13, 2009, and November 5, 2012.Main Outcomes and Measures: Corneal hysteresis after CXL for keratoconus.Results: A difference in corneal hysteresis between the control group and the patients with keratoconus was found at baseline, both with an applanation resonance tonometer (ART) and an ocular response analyzer (ORA), at mean (SD) values of -1.09 (1.92) mm Hg (99% CI, -2.26 to 0.07; P = .01) and -2.67 (2.55) mm Hg (99% CI, -4.05 to -1.32; P < .001), respectively. Increased corneal hysteresis was demonstrated with an ART 1 and 6 months after CXL, at 1.2 (2.4) mm Hg (99% CI,-0.1 to 2.5; P = .02) and 1.1 (2.7) mm Hg (99% CI, -0.3 to 2.6; P = .04), respectively, but not with ORA. A decrease in corneal thickness was seen 1 and 6 months after treatment (-24 [26] µm, P < .001; and -11 [21] µm, P = .01, respectively), and a corneal flattening of -0.6 (0.7) diopters was seen at 6 months (P < .001). No significant change in intraocular pressure was identified in patients with keratoconus with any method, except for an increase at 1 month with Goldmann applanation tonometry (P = .005).Conclusions and Relevance: To our knowledge ART is the first in vivo method able to assess the increased corneal hysteresis after CXL treatment. Given the large-scale use of CXL in modern keratoconus treatment, a tool with this capacity has a great potential value. Refinement of the ART method of measuring and quantifying corneal biomechanical properties will be a subject of further studies.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Beckman Rehnman, ...
Behndig, Anders
Hallberg, Per
Lindén, Christin ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Oftalmologi
Artiklar i publikationen
JAMA ophthalmolo ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy