SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Blomberg Björn)
 

Sökning: WFRF:(Blomberg Björn) > Is quantitative PCR...

Is quantitative PCR for the pneumolysin (ply) gene useful for detection of pneumococcal lower respiratory tract infection?

Abdeldaim, Guma (författare)
Uppsala universitet,Klinisk bakteriologi,Herrmann
Herrmann, Björn (författare)
Uppsala universitet,Klinisk bakteriologi,Herrmann
Korsgaard, J. (författare)
Köpenhamns Universitet
visa fler...
Olcén, P. (författare)
Örebro Universitet, klinisk mikrobiologi
Blomberg, Jonas (författare)
Uppsala universitet,Klinisk virologi
Strålin, Kristoffer (författare)
Örebro Universitet, klinisk mikrobiologi
visa färre...
 (creator_code:org_t)
Elsevier BV, 2009
2009
Engelska.
Ingår i: Clinical Microbiology and Infection. - : Elsevier BV. - 1198-743X .- 1469-0691. ; 15:6, s. 565-570
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The pneumolysin (ply) gene is widely used as a target in PCR assays for Streptococcus pneumoniae in respiratory secretions. However, false-positive results with conventional ply-based PCR have been reported. The aim here was to study the performance of a quantitative ply-based PCR for the identification of pneumococcal lower respiratory tract infection (LRTI). In a prospective study, fibreoptic bronchoscopy was performed in 156 hospitalized adult patients with LRTI and 31 controls who underwent bronchoscopy because of suspicion of malignancy. Among the LRTI patients and controls, the quantitative ply-based PCR applied to bronchoalveolar lavage (BAL) fluid was positive at >/=10(3) genome copies/mL in 61% and 71% of the subjects, at >/=10(5) genome copies/mL in 40% and 58% of the subjects, and at >/=10(7) genome copies/mL in 15% and 3.2% of the subjects, respectively. Using BAL fluid culture, blood culture, and/or a urinary antigen test, S. pneumoniae was identified in 19 LRTI patients. As compared with these diagnostic methods used in combination, quantitative ply-based PCR showed sensitivities and specificities of 89% and 43% at a cut-off of 10(3) genome copies/mL, of 84% and 66% at a cut-off of 10(5) genome copies/mL, and of 53% and 90% at a cut-off of 10(7) genome copies/mL, respectively. In conclusion, a high cut-off with the quantitative ply-based PCR was required to reach acceptable specificity. However, as a high cut-off resulted in low sensitivity, quantitative ply-based PCR does not appear to be clinically useful. Quantitative PCR methods for S. pneumoniae using alternative gene targets should be evaluated.

Nyckelord

Bronchoalveolar lavage
PCR
pneumolysin
pneumonia
Streptococcus pneumoniae
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy