Sökning: L773:1097 0231 OR L773:0951 4198 >
Quantitative determ...
Quantitative determination of cetirizine enantiomers in guinea pig plasma, brain tissue and microdialysis samples using liquid chromatography/tandem mass spectrometry
-
- Gupta, Anubha (författare)
- Uppsala universitet,Avdelningen för farmakokinetik och läkemedelsterapi,Hammarlund-Udenaes
-
- Jansson, Britt (författare)
- Uppsala universitet,Avdelningen för farmakokinetik och läkemedelsterapi,Hammarlund-Udenaes
-
Chatelain, Pierre (författare)
-
visa fler...
-
Massingham, Roy (författare)
-
- Hammarlund-Udenaes, Margareta (författare)
- Uppsala universitet,Avdelningen för farmakokinetik och läkemedelsterapi,Hammarlund-Udenaes
-
visa färre...
-
(creator_code:org_t)
- 2005
- 2005
- Engelska.
-
Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 0951-4198 .- 1097-0231. ; 19:12, s. 1749-1757
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Sensitive enantioselective liquid chromatographic assays using tandem mass spectrometric detection were developed and validated for the determination of S-cetirizine (S-CZE) and R-cetirizine (R-CZE) in guinea pig plasma, brain tissue, and microdialysis samples. Enantioselective separation was achieved on an alpha1-acid glycoprotein column within 14 min for all methods. A cetirizine analog, ucb 20028, was used as internal standard. Cetirizine and the internal standard were detected by multiple reaction monitoring using transitions m/z 389.1 --> 200.9 and 396.1 --> 276.1, respectively. The samples were prepared using protein precipitation with acetonitrile. For guinea pig plasma, the assay was linear over the range 0.25-5000 ng/mL for both S-CZE and R-CZE, with a lower limit of quantification (LLOQ) of 0.25 ng/mL. For the brain tissue and microdialysis samples, the assays were linear over the range 2.5-250 ng/g and 0.25-50 ng/mL, respectively, and the LLOQ values were 2.5 ng/g and 0.25 ng/mL, respectively. The intra- and inter-day precision values were < or =7.1% and < or =12.6%, respectively, and the intra- and inter-day accuracy varied by less than +/-8.0% and +/-6.0% of the nominal value, respectively, for both enantiomers in all the matrices investigated.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinska och farmaceutiska grundvetenskaper -- Farmaceutiska vetenskaper (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Basic Medicine -- Pharmaceutical Sciences (hsv//eng)
Nyckelord
- PHARMACY
- FARMACI
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas