Reference jitter values for concentric needle electrodes in voluntarily activated extensor digitorum communis and orbicularis oculi muscles.

Kouyoumdjian, João Aris (författare)
Stålberg, Erik V. (författare)
Uppsala universitet,Institutionen för neurovetenskap,Klinisk neurofysiologi
 (creator_code:org_t)
Wiley, 2008
2008
Engelska.
Ingår i: Muscle and Nerve. - : Wiley. - 0148-639X .- 1097-4598. ; 37:6, s. 694-699
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this study was to estimate normal jitter in voluntarily activated extensor digitorum communis (EDC) and orbicularis oculi (OOc) muscles using a disposable concentric needle electrode (CNE). The EDC of 67 normal subjects (22 males and 45 females, mean age 35.5 ± 10.2 years) and the OOc of 50 normal subjects (13 males and 37 females, mean age 37.9 ± 9.6 years) were studied. Jitter values were expressed as the mean consecutive difference (MCD) of 20 potential pairs. The mean MCD for EDC was 23.6 ± 3.1 µs (upper 95% confidence limit [CL]: 29.7 µs). The mean MCD of all potential pairs (n = 1340) was 23.5  ± 7.3 µs (95% CL: 38.2 µs). The mean MCD for the 18th highest value was 31.4 ± 4.9 µs (95% CL: 41.2 µs). The mean MCD for OOc was 24.7 ± 3.1 µs (95% CL: 31.0 µs). The mean MCD of all potential pairs (n = 1000) was 24.7 ± 7.1 µs (95% CL: 39.0 µs). The mean MCD for the 18th highest value was 32.7 ± 4.1 µs (95% CL: 40.9 µs). Our reported CNE jitter values obtained during voluntary activation represent the largest series currently available. The suggested practical limit in the EDC for mean MCD was 30 µs and for outliers was 42 µs, and in the OOc for mean MCD was 31 µs and 41 µs for outliers. The present study confirms that CNE can be used to assess jitter values, although certain precautions must be taken.

Nyckelord

Concentric needle electrode
extensor digitorum communis
jitter
orbicularis oculi
single-fiber electromyography

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Kouyoumdjian, Jo ...
Stålberg, Erik V ...
Artiklar i publikationen
Muscle and Nerve
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy