SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Blessborn Daniel)
 

Sökning: WFRF:(Blessborn Daniel) > Simultaneous quanti...

Simultaneous quantitation of the highly lipophilic atovaquone and hydrophilic strong basic proguanil and its metabolites using a new mixed-mode SPE approach and steep-gradient LC

Lindegårdh, Niklas (författare)
Uppsala universitet,Analytisk kemi,Dalarna University College, 781 88 Borlänge; and Uppsala University, Department of Analytical Chemistry, 751 21 Uppsala, Sweden
Blessborn, Daniel (författare)
Högskolan Dalarna,Uppsala universitet,Analytisk kemi,Dalarna University College, 781 88 Borlänge; and Uppsala University, Department of Analytical Chemistry, 751 21 Uppsala, Sweden,Kemiteknik
Bergqvist, Yngve (författare)
Högskolan Dalarna,Uppsala universitet,Analytisk kemi,Dalarna University College, 781 88 Borlänge; and Uppsala University, Department of Analytical Chemistry, 751 21 Uppsala, Sweden,Kemiteknik
 (creator_code:org_t)
Oxford University Press (OUP), 2005
2005
Engelska.
Ingår i: Journal of Chromatographic Science. - : Oxford University Press (OUP). - 0021-9665 .- 1945-239X. ; 43:5, s. 259-266
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A bioanalytical method is described for the simultaneous quantitative analysis of the highly lipophilic atovaquone and the strong basic proguanil with metabolites in plasma. The drugs are extracted from protein precipitated plasma samples on a novel mixed-mode solid-phase extraction (SPE) column containing carboxypropyl and octyl silica as functional groups. The analytes are further separated and quantitated using a steep-gradient liquid chromatographic method on a Zorbax SB-CN column with UV detection at 245 nm. Two different internal standards (IS) are used in the method to compensate for both types of analytes. A structurally similar IS to atovaquone is added with acetonitrile to precipitate proteins from plasma. A structurally similar IS to proguanil and its metabolites is added with phosphate buffer before samples are loaded onto the SPE columns. A single elution step is sufficient to elute all analytes. The method is validated according to published guidelines and shows excellent performance. The within-day precisions, expressed as relative standard deviation, are lower than 5% for all analytes at three tested concentrations within the calibration range. The between-day precisions are lower than 13% for all analytes at the same tested concentrations. The limit of quantitation is 25 nM for the basic substances and 50 nM for atovaquone. Several considerations regarding development and optimization of a method for determination of analytes with such a difference in physiochemical properties are discussed.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Kemiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Lindegårdh, Nikl ...
Blessborn, Danie ...
Bergqvist, Yngve
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Kemiteknik
Artiklar i publikationen
Journal of Chrom ...
Av lärosätet
Uppsala universitet
Högskolan Dalarna

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy