Quantitative PCR analysis of fungal DNA in Swedish day care centers and comparison with building characteristics and allergen levels

Cai, G-H (författare)
Uppsala universitet,Arbets- och miljömedicin
Bröms, Kristina (författare)
Uppsala universitet,Allmänmedicin och klinisk epidemiologi
Mälarstig, B (författare)
visa fler...
Zhao, Z-H (författare)
Uppsala universitet,Arbets- och miljömedicin,eva vingård
Kim, Jeong-Lim (författare)
Gothenburg University,Göteborgs universitet,Uppsala universitet,Arbets- och miljömedicin,eva vingård,Institutionen för medicin, avdelningen för samhällsmedicin och folkhälsa,Institute of Medicine, School of Public Health and Community Medicine
Svärdsudd, Kurt (författare)
Uppsala universitet,Allmänmedicin och klinisk epidemiologi
Janson, Christer (författare)
Uppsala universitet,Lungmedicin och allergologi
Norbäck, Dan (författare)
Uppsala universitet,Arbets- och miljömedicin
visa färre...
 (creator_code:org_t)
Hindawi Limited, 2009
2009
Engelska.
Ingår i: Indoor Air. - : Hindawi Limited. - 0905-6947 .- 1600-0668. ; 19:5, s. 392-400
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  •  Sweden has had allergen-avoidance day care centers (AADCs) since 1979. The aim of this study was to measure fungal DNA by quantitative polymerase chain reaction (qPCR), a new method, in AADCs and ordinary day care centers (ODCs) and examine associations between allergen levels and building characteristics. Dust samples were collected by swabbing doorframes, vacuum-cleaning, and using Petri dishes. In total, 11 AADCs and 11 ODCs were studied (70 rooms). Total fungal DNA, measured by qPCR in the swab dust, was detected in 89%, Aspergillus or Penicillium (Asp/Pen) DNA in 34%, and Stachybotrys chartarum DNA in 6% of the rooms. Total fungal DNA was significantly higher in rooms with linoleum floor (P = 0.02), textile carpets (P = 0.03), reported dampness/molds (P = 0.02) and reported odor (P < 0.001) in the buildings, and significantly lower in wooden facade buildings (P = 0.003). Reported odor was related to the amount of sieved fine dust, reported dampness/molds and type of building construction. Total fungal DNA was related to cat, dog, horse and total allergen levels (P = 0.003) in the day care centers. In conclusion, total fungal DNA is related to reported dampness/molds, reported odor, and type of wall construction. The association between fungal and allergen contamination indicated a general 'hygiene factor' related to biological contaminants. Practical Implications The associations between fungal DNA, reported dampness/molds, and odor support the view that buildings with odor problems should be investigated for possible hidden fungal growth. There is a need to measure fungal biomass in different types of building constructions by monitoring fungal DNA. Analysis of fungal DNA with quantitative PCR can be a fast and practical way to study indoor fungal contamination. Swabbing dust from the doorframe of the main entrance to the room can be a convenient method of sampling dust for fungal DNA analysis. The high prevalence of reported dampness/molds and the common occurrence of fungal DNA indicate the need to improve the indoor environment of Swedish day care centers.

Ämnesord

SAMHÄLLSVETENSKAP  -- Annan samhällsvetenskap -- Övrig annan samhällsvetenskap (hsv//swe)
SOCIAL SCIENCES  -- Other Social Sciences -- Other Social Sciences not elsewhere specified (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Mikrobiologi inom det medicinska området (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Microbiology in the medical area (hsv//eng)

Nyckelord

Day care centers
Quantitative PCR
Fungal DNA
Allergen levels
Indoor environment
Building dampness
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy