SwePub
Sök i LIBRIS databas

  Utökad sökning

(WFRF:(Rominger Axel))
 

Sökning: (WFRF:(Rominger Axel)) > Validation of the O...

Validation of the Octamouse for Simultaneous 18F-Fallypride Small-Animal PET Recordings from 8 Mice

Rominger, Axel (författare)
Mille, Erik (författare)
Zhang, Shanshan (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
visa fler...
Boening, Guido (författare)
Foerster, Stefan (författare)
Nowak, Sebastian (författare)
Gildehaus, Franz Josef (författare)
Waengler, Bjoern (författare)
Bartenstein, Peter (författare)
Cumming, Paul (författare)
visa färre...
 (creator_code:org_t)
2010-09-16
2010
Engelska.
Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 51:10, s. 1576-1583
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Data collection in preclinical small-animal PET studies has been hindered by the small number of recordings typically obtained for a single radiosynthesis. Therefore, we tested procedures for obtaining 8 simultaneous small-animal PET recordings from the brains of 8 mice using an acrylic anesthesia distributor (the Octamouse), with the dopamine D-2/3 ligand F-18-fallypride serving as a test substance for brain receptor imaging. Methods: The effect of scatter correction on the small-animal PET recordings was first evaluated in phantom studies in which sources of different radioactivity concentration were placed within the chambers of the Octamouse. Next, potential effects of mass on the F-18-fallypride binding potential (BPND) in the striatum were tested in groups of mice receiving F-18-fallypride at 2 different specific activities (140 and 50 GBq/mu mol), with and without scatter correction. Finally, the relationship between BPND and injected dose of F-18-fallypride (3.5-17 MBq/mouse) was tested. Results: Scatter correction improved the contrast between sources and air space within the Octamouse phantom. The magnitude of F-18-fallypride BPND in mouse striatum was invariant across the tested range of specific activities, and scatter correction increased BPND by a mean of 6%; covariances of the inter-and intraoperator variability of BPND were 10%. There was a positive correlation between radiochemical dose and BPND with (R-2 = 0.53) and without (R-2 = 0.63) scatter correction, which was driven by increasing area under the percentage injected dose curve in the striatum. Conclusion: The quantitation of emission sources placed within the Octamouse is linear over a wide range of source activities. In the striatum of living mice, the magnitude of F-18-fallypride BPND was highly reproducible between operators and was constant over a 3-fold range of specific activities, indicating a lack of significant occupancy. Scatter correction improved quantitation but did not entirely correct for the dependence of BPND on injected dose, which was deemed to arise because of effects propagating from detector dead time when the total radiochemical dose in the field of view exceeded 50 MBq. Given this consideration, we were still able to quantify F-18-fallypride BPND in 16 mice from a single radiosynthesis, an economy that should be generalizable to brain studies of diverse radioligands.

Nyckelord

Octamouse holder
dopamine D-2/3 receptor
fallypride
small-animal PET
mouse brain
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy