SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Shlipak Michael G)
 

Sökning: WFRF:(Shlipak Michael G) > Comparison of Cardi...

  • Shlipak, Michael G. (författare)

Comparison of Cardiovascular Prognosis by 3 Serum Cystatin C Methods in the Heart and Soul Study

  • Artikel/kapitelEngelska2011

Förlag, utgivningsår, omfång ...

  • 2011-05-01
  • Oxford University Press (OUP),2011
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-149738
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-149738URI
  • https://doi.org/10.1373/clinchem.2010.158915DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • BACKGROUND: Cystatin C is a promising new biomarker to estimate glomerular filtration (eGFR). However, the Siemens' cystatin C assay (Siemens), used in many longitudinal studies, has had limited clinical applicability because it requires a specific, dedicated instrument. Other companies, including Gentian and Roche, have developed cystatin C assays that can be used with most routine clinical chemistry analyzers. METHODS: We compared the agreement of Gentian and Roche with Siemens in 948 participants at the baseline visit of the Heart and Soul Study, a cohort of participants with established coronary artery disease who were followed for an average of 8 years. We then compared associations of all 3 cystatin C measures and eGFR-Modification of Diet in Renal Disease (MDRD) with clinical outcomes. RESULTS: The Gentian assay had higher correlation with Siemens (r = 0.96) than did Roche (r = 0.93, P < 0.001). After cross-tabulating quartiles of each cystatin C measure, agreements (κ statistic) were higher for Siemens and Gentian (0.73, 95% CI 0.72-0.75) than for Roche and Siemens (0.64, 0.63-0.66) or for Roche and Gentian (0.69, 0.65-0.71). These differences in agreement had minimal impact on associations with clinical outcomes; the hazard ratios (HRs) for mortality comparing the high vs low quartiles were 3.2 (95% CI 2.1-4.8) for Siemens, 3.1 (CI 2.1-4.7) for Gentian, 3.1 (CI 2.1-4.7) for Roche, and 1.6 (CI 1.1-2.3) for eGFR-MDRD, after multivariate adjustment. CONCLUSIONS: In summary, agreement with the Siemens' assay was modestly higher for the Gentian compared with the Roche assay, although all 3 methods for cystatin C measurement had similar utility as predictors of clinical outcomes.

Ämnesord och genrebeteckningar

  • MEDICINE
  • MEDICIN

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Weekley, Cristin C. (författare)
  • Li, Yongmei (författare)
  • Hansson, Lars-OlofUppsala universitet,Klinisk kemi,biologisk struktur och funktion (författare)
  • Larsson, AndersUppsala universitet,Klinisk kemi,biologisk struktur och funktion(Swepub:uu)andla606 (författare)
  • Whooley, Mary (författare)
  • Uppsala universitetKlinisk kemi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Clinical Chemistry: Oxford University Press (OUP)57:5, s. 737-7450009-91471530-8561

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy