SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-154905"
 

Sökning: id:"swepub:oai:DiVA.org:uu-154905" > Optimisation of pos...

  • Dellaca, Raffaele L. (författare)

Optimisation of positive end-expiratory pressure by forced oscillation technique in a lavage model of acute lung injury

  • Artikel/kapitelEngelska2011

Förlag, utgivningsår, omfång ...

  • 2011-04-01
  • Springer Science and Business Media LLC,2011
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-154905
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-154905URI
  • https://doi.org/10.1007/s00134-011-2211-7DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • We evaluated whether oscillatory compliance (C-X5) measured by forced oscillation technique (FOT) at 5 Hz may be useful for positive end-expiratory pressure (PEEP) optimisation. We studied seven pigs in which lung injury was induced by broncho-alveolar lavage. The animals were ventilated in volume control mode with a tidal volume of 6 ml/kg. Forced oscillations were superimposed on the ventilation waveform for the assessment of respiratory mechanics. PEEP was increased from 0 to 24 cmH(2)O in steps of 4 cmH(2)O and subsequently decreased from 24 to 0 in steps of 2 cmH(2)O. At each 8-min step, a CT scan was acquired during an end-expiratory hold, and blood gas analysis was performed. C-X5 was monitored continuously, and data relative to the expiratory hold were selected and averaged for comparison with CT and oxygenation. Open lung PEEP (PEEPol) was defined as the level of PEEP corresponding to the maximum value of C-X5 on the decremental limb of the PEEP trial. PEEPol was on average 13.4 (+/- 1.0) cmH(2)O. For higher levels of PEEP, there were no significant changes in the amount of non-aerated tissue (V-tissNA%). In contrast, when PEEP was reduced below PEEPol, V-tissNA% dramatically increased. PEEPol was able to prevent a 5% drop in V-tissNA% with 100% sensitivity and 92% specificity. At PEEPol V-tissNA% was significantly lower than at the corresponding PEEP level on the incremental limb. The assessment of C-X5 allowed the definition of PEEPol to be in agreement with CT data. Thus, FOT measurements of C-X5 may provide a non-invasive bedside tool for PEEP titration.

Ämnesord och genrebeteckningar

  • Forced oscillation technique
  • Lung mechanics
  • Mechanical ventilation
  • Positive end-expiratory pressure
  • Lung volume recruitment
  • Computed tomography
  • ARDS
  • MEDICINE
  • MEDICIN

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Zannin, Emanuela (författare)
  • Kostic, PeterUppsala universitet,Anestesiologi och intensivvård(Swepub:uu)petko435 (författare)
  • Olerud, Marie AnderssonUppsala universitet,Anestesiologi och intensivvård (författare)
  • Pompilio, Pasquale P. (författare)
  • Hedenstierna, GöranUppsala universitet,Klinisk fysiologi(Swepub:uu)goranhed (författare)
  • Pedotti, Antonio (författare)
  • Frykholm, PeterUppsala universitet,Anestesiologi och intensivvård(Swepub:uu)petefryk (författare)
  • Uppsala universitetAnestesiologi och intensivvård (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Intensive Care Medicine: Springer Science and Business Media LLC37:6, s. 1021-10300342-46421432-1238

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy