SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Andrén Per E.)
 

Sökning: WFRF:(Andrén Per E.) > Poly(dimethylsiloxa...

Poly(dimethylsiloxane)-Based Microchip for Two-Dimensional Solid-Phase Extraction-Capillary Electrophoresis with an Integrated Electrospray Emitter Tip

Dahlin, Andreas P. (författare)
Uppsala universitet,Avdelningen för analytisk kemi
Bergström, Sara K. (författare)
Uppsala universitet,Avdelningen för analytisk kemi
Andrén, Per E. (författare)
Uppsala universitet,MMS, medicinsk masspektrometri
visa fler...
Markides, Karin E. (författare)
Uppsala universitet,Avdelningen för analytisk kemi
Bergquist, Jonas (författare)
Uppsala universitet,Avdelningen för analytisk kemi
visa färre...
 (creator_code:org_t)
2005-07-06
2005
Engelska.
Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 77:16, s. 5356-5363
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A microchip in poly(dimethylsiloxane) (PDMS) for in-line solid-phase extraction-capillary electrophoresis-electrospray ionization-time-of-flight mass spectrometry (SPE-CE-ESI-TOF-MS) has been developed and evaluated. The chip was fabricated in a novel one-step procedure where mixed PDMS was cast over steel wires in a mold. The removed wires defined 50-um cylindrical channels. Fused-silica capillaries were inserted into the structure in a tight fit connection. The inner walls of the inserted fused-silica capillaries and the PDMS microchip channels were modified with a positively charged polymer, PolyE-323. The chip was fabricated in a two-level cross design. The channel at the lower level was packed with 5-um hyper-cross-linked polystyrene beads acting as a SPE medium used for desalting. The upper level channel acted as a CE channel and ended in an integrated emitter tip coated with conducting graphite powder to facilitate the electrical contact for sheathless ESI. An overpressure continuously provided fresh CE electrolyte independently of the flows in the different levels. Further studies were carried out in order to investigate the electrophoretic and flow rate properties of the chip. Finally, six-peptide mixtures, in different concentrations, dissolved in physiological salt solution was injected, desalted, separated, and sprayed into the mass spectrometer for analysis with a limit of detection in femtomole levels.

Ämnesord

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Nyckelord

Chemistry
Kemi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy