SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sophie )
 

Sökning: WFRF:(Sophie ) > Body composition of...

Body composition of Bangladeshi children: comparison and development of  leg-to-leg bioelectrical impedance equation

Khan, Ashraful, 1969- (författare)
Uppsala universitet,Internationell mödra- och barnhälsovård (IMCH)
Hawkesworth, Sophie (författare)
Hawlader, Mohammad Delwer Hossain (författare)
visa fler...
Arifeen, Shams (författare)
Moore, Sophie (författare)
Hills, Andrew (författare)
Wells, Jonathan (författare)
Persson, Lars-Åke (författare)
Uppsala universitet,Internationell mödra- och barnhälsovård (IMCH)
Kabir, Iqbal (författare)
visa färre...
 (creator_code:org_t)
2012
2012
Engelska.
Ingår i: Journal of Health, Population and Nutrition. - 1606-0997 .- 2072-1315. ; 30:3, s. 281-290
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this study was to investigate the validity of the Tanita TBF 300A leg-to-leg bioimpedance analyzer for estimating fat-free mass (FFM) in Bangladeshi children aged 4-10 years and to develop novel prediction equations for use in this population, using deuterium dilution as the reference method. Two hundred Bangladeshi children were enrolled. The isotope dilution technique with deuterium oxide was used for estimation of total body water (TBW).  FFM estimated by Tanita was compared to results of deuterium oxide dilution technique. Novel prediction equations were created for estimating FFM, using linear regression models, fitting child height and impedance as predictors.  There was a significant difference in FFM and BF% (percentage of body fat) between methods (p<0.01), Tanita under-estimating TBW in boys (p=0.001) and under-estimating BF% in girls (p<0.001). A basic linear regression model with height and impedance explained 83% of the variance in FFM estimated by deuterium oxide dilution. The best fit equation to predict FFM from linear regression modeling was achieved by adding weight, sex and age to the basic model, bringing the adjusted R2 to 89% (standard error=0.90, p<0.001). These data suggest Tanita analyzer may be a valid field assessment technique in Bangladeshi children when using population-specific prediction equations such as the ones developed here. 

Nyckelord

Bioelectrical impedance
Body composition
Children
Deuterium oxide dilution
Bangladesh

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy