SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Knaapen P.)
 

Search: WFRF:(Knaapen P.) > (2011-2014) > Parametric Images o...

  • Harms, Hendrik J (author)

Parametric Images of Myocardial Viability Using a Single 15O-H2O PET/CT Scan

  • Article/chapterEnglish2011

Publisher, publication year, extent ...

  • 2011-04-15
  • Society of Nuclear Medicine,2011
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:uu-189079
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-189079URI
  • https://doi.org/10.2967/jnumed.110.085431DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Perfusable tissue index (PTI) is a marker of myocardial viability and requires acquisition of transmission, 15O-CO, and 15O-H2O scans. The aim of this study was to generate parametric PTI images from a 15O-H2O PET/CT scan without an additional 15O-CO scan.Methods:Data from 20 patients undergoing both 15O-H2O and 15O-CO scans were used, assessing correlation between PTI based on 15O-CO (PTICO) and on fitted blood volume fractions (PTIVb). In addition, parametric PTIVb images of 10 patients undergoing 15O-H2O PET/CT scans were generated using basis-function methods and compared with PTIVb obtained using nonlinear regression. Simulations were performed to study the effects of noise on PTIVb.Results:Correlation between PTICO and PTIVb was high (r2 = 0.73). Parametric PTIVb correlated well with PTIVb obtained using nonlinear regression (r2 = 0.91). Simulations showed low sensitivity to noise (coefficient of variation < 10% at 20% noise).Conclusion:Parametric PTI images can be generated from a single 15O-H2O PET/CT scan.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • de Haan, Stefan (author)
  • Knaapen, Paul (author)
  • Allaart, Cornelis P (author)
  • Lammertsma, Adriaan A (author)
  • Lubberink, MarkDepartment of Nuclear Medicine and PET Research, VU University Medical Center, Amsterdam, The Netherlands(Swepub:uu)marklubb (author)
  • Department of Nuclear Medicine and PET Research, VU University Medical Center, Amsterdam, The Netherlands (creator_code:org_t)

Related titles

  • In:Journal of Nuclear Medicine: Society of Nuclear Medicine52:5, s. 745-7490161-55051535-56672159-662X

Internet link

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view