SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Carling Tobias)
 

Sökning: WFRF:(Carling Tobias) > (2010-2014) > 4D parathyroid CT a...

4D parathyroid CT as the initial localization study for patients with de novo primary hyperparathyroidism

Starker, Lee F (författare)
Uppsala universitet,Experimentell kirurgi,Department of Surgery, Yale University School of Medicine, New Haven, CT, USA
Mahajan, Amit (författare)
Björklund, Peyman (författare)
Uppsala universitet,Experimentell kirurgi,Department of Surgery, Yale University School of Medicine, New Haven, CT, USA
visa fler...
Sze, Gordon (författare)
Udelsman, Robert (författare)
Carling, Tobias (författare)
visa färre...
 (creator_code:org_t)
2010-12-24
2011
Engelska.
Ingår i: Annals of Surgical Oncology. - : Springer Science and Business Media LLC. - 1068-9265 .- 1534-4681. ; 18:6, s. 1723-1728
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND:Preoperative localization of parathyroid tumors of primary hyperparathyroidism (pHPT) is required for minimally invasive parathyroidectomy (MIP). Parathyroid four-dimensional computed tomography (4DCT) has mainly been used as an adjunct to other imaging modalities in the remedial setting. 4DCT was evaluated as the initial localization study in de novo patients with pHPT.MATERIALS AND METHODS:A total of 87 consecutive patients underwent parathyroidectomy for pHPT from August 2008 to November 2009. 4DCT was introduced as the preferred imaging modality instead of sestamibi with SPECT (SeS) in April 2009. Results of the imaging studies [4DCT, SeS, and ultrasonography (US)], operative and, pathologic findings, and biochemical measurements were evaluated.RESULTS:In this study, 84% of patients (73 of 87) underwent an US, 59.8% (52 of 87) a SeS, and 38.0% (33 of 87) had a 4DCT. 4DCT had improved sensitivity (85.7%) over SeS (40.4%) and US (48.0%) to localize parathyroid tumors to the correct quadrant of the neck (P < 0.005) as well as to localize (lateralize) the parathyroid lesions to one side of the neck (93.9% for 4DCT vs. 71.2% for US and 61.5% for SeS; P < 0.005). 4DCT correctly predicted multiglandular disease (MGD) in 85.7% (6 of 7) patients, whereas US and SeS were unable to detect MGD in any case. All patients achieved cure based on intraoperative parathyroid hormone (PTH) measurements and normalization of intact PTH and S-Ca during follow-up.CONCLUSIONS:4DCT provides significantly greater sensitivity than SeS and US for precise localization of parathyroid tumors of pHPT. Additionally, it correctly predicted MGD in a majority of patients.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy