SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Eilers Gerriet)
 

Sökning: WFRF:(Eilers Gerriet) > Evaluation of Intra...

Evaluation of Intracavity Optogalvanic Spectroscopy for Radiocarbon Measurements

Persson, Anders (författare)
Uppsala universitet,Tillämpad kärnfysik,Ion Physics
Eilers, Gerriet (författare)
Uppsala universitet,Tillämpad kärnfysik,Ion Physics
Ryderfors, Linus (författare)
Uppsala universitet,Tillämpad kärnfysik,Ion Physics
visa fler...
Mukhtar, Emad (författare)
Uppsala universitet,Fysikalisk kemi
Possnert, Göran (författare)
Uppsala universitet,Tillämpad kärnfysik,Ion Physics
Salehpour, Mehran (författare)
Uppsala universitet,Tillämpad kärnfysik,Ion Physics
visa färre...
 (creator_code:org_t)
2013-06-24
2013
Engelska.
Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 85ASAP:14, s. 6790-6798
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Ever since the first publication of intracavity optogalvanic spectroscopy (ICOGS) in 2008, this novel technique for measuring the 14C/12C ratio in carbon dioxide has rendered considerable attention. As a result, there are currently at least five different research groups pursuing research on ICOGS. With a claimed limit of detection of 10–15 (14C/12C), i.e., in the same order as accelerator mass spectroscopy, achieved with a relatively inexpensive and uncomplicated table-top system, ICOGS has major scientific and commercial implications. However, during the past 5 years, no research group has been able to reproduce these results or present additional proof for ICOGS’s capability of unambiguous 14C detection, including the authors of the original publication. Starting in 2010, our group has set up a state-of-the-art ICOGS laboratory and has investigated the basic methodology of ICOGS in general and tried to reproduce the reported experiments in particular. We have not been able to reproduce the reported results concerning the optogalvanic signals dependence on14C concentration and wavelength and, ultimately, not seen any evidence of the capability of ICOGS to unambiguously detect 14C at all. Instead, we have found indications that the reported results can be products of measurement uncertainties and mistakes. Furthermore, our results strongly indicate that the reported limit of detection is likely to be overestimated by at least 2 orders of magnitude, based on the results presented in the original publication. Hence, we conclude that the original reports on ICOGS cannot be confirmed and therefore must be in error.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)
NATURVETENSKAP  -- Fysik -- Fusion, plasma och rymdfysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Fusion, Plasma and Space Physics (hsv//eng)

Nyckelord

Intracavity optogalvanic spectroscopy
radiocarbon laser spectroscopy
14CO2 lasers
14C detection
CO2 oscillations
Analytical Chemistry
Analytisk kemi
Ion Physics
Jonfysik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy