SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Koning Arjan J.)
 

Sökning: WFRF:(Koning Arjan J.) > Total Monte Carlo e...

Total Monte Carlo evaluation for dose calculations

Sjöstrand, Henrik (författare)
Uppsala universitet,Tillämpad kärnfysik,Nuclear Reactions Group
Alhassan, Erwin (författare)
Uppsala universitet,Tillämpad kärnfysik,Nuclear Research Group
Conroy, Sean (författare)
Uppsala universitet,Tillämpad kärnfysik
visa fler...
Duan, Junfeng (författare)
Uppsala universitet,Tillämpad kärnfysik,Nuclear Reactions Group
Hellesen, Carl (författare)
Uppsala universitet,Tillämpad kärnfysik
Pomp, Stephan (författare)
Uppsala universitet,Tillämpad kärnfysik,Nuclear Reactions Group
Österlund, Michael (författare)
Uppsala universitet,Tillämpad kärnfysik,Nuclear Reaction Group
Arjan, Koning J. (författare)
Uppsala universitet,Tillämpad kärnfysik,Nuclear Research and Consultancy Group
Dimitri, Rochman (författare)
Nuclear Research and Consultancy Group
visa färre...
 (creator_code:org_t)
2013-11-24
2014
Engelska.
Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 161:1-4, s. 312-315
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Total Monte Carlo (TMC) is a method to propagate nuclear data (ND) uncertainties in transport codes, by using a large set of ND files, which covers the ND uncertainty. The transport code is run multiple times, each time with a unique ND file, and the result is a distribution of the investigated parameter, e.g. dose, where the width of the distribution is interpreted as the uncertainty due to ND. Until recently, this was computer intensive, but with a new development, fast TMC, more applications are accessible. The aim of this work is to test the fast TMC methodology on a dosimetry application and to propagate the 56Fe uncertainties on the predictions of the dose outside a proposed 14-MeV neutron facility. The uncertainty was found to be 4.2 %. This can be considered small; however, this cannot be generalised to all dosimetry applications and so ND uncertainties should routinely be included in most dosimetry modelling.

Ämnesord

NATURVETENSKAP  -- Fysik -- Annan fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Other Physics Topics (hsv//eng)

Nyckelord

Applied Nuclear Physics
Tillämpad kärnfysik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy