SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Haybaeck Johannes)
 

Sökning: WFRF:(Haybaeck Johannes) > Sensitivity and Spe...

  • Zatloukal, Bernhard (författare)

Sensitivity and Specificity of In situ Proximity Ligation for Protein Interaction Analysis in a Model of Steatohepatitis with Mallory-Denk Bodies

  • Artikel/kapitelEngelska2014

Förlag, utgivningsår, omfång ...

  • 2014-05-05
  • Public Library of Science (PLoS),2014
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-228028
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-228028URI
  • https://doi.org/10.1371/journal.pone.0096690DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • The in situ proximity ligation assay (isPLA) is an increasingly used technology for in situ detection of protein interactions, post-translational modifications, and spatial relationships of antigens in cells and tissues, in general. In order to test its performance we compared isPLA with immunofluorescence microscopy by analyzing protein interactions in cytoplasmic protein aggregates, so-called Mallory Denk bodies (MDBs). These structures represent protein inclusions in hepatocytes typically found in human steatohepatitis and they can be generated in mice by feeding of 3,5-diethoxy-carbonyl-1,4-dihydrocollidine (DDC). We investigated the colocalization of all three key MDB components, namely keratin 8 (K8), keratin 18 (K18), and p62 (sequestosome 1) by isPLA and immunofluorescence microscopy. Sensitivity and specificity of isPLA was assessed by using Krt8(-/-) and Krt18(-/-) mice as biological controls, along with a series of technical controls. isPLA signal visualization is a robust technology with excellent sensitivity and specificity. The biological relevance of signals generated critically depends on the performance of antibodies used, which requires careful testing of antibodies like in immunofluorescence microscopy. There is a clear advantage of isPLA in visualizing protein co-localization, particularly when antigens are present at markedly different concentrations. Furthermore, isPLA is superior to confocal microscopy with respect to spatial resolution of colocalizing antigens. Disadvantages compared to immunofluorescence are increased costs and longer duration of the laboratory protocol.

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Kufferath, Iris (författare)
  • Thueringer, Andrea (författare)
  • Landegren, UlfUppsala universitet,Molekylära verktyg(Swepub:uu)ulfland (författare)
  • Zatloukal, Kurt (författare)
  • Haybaeck, Johannes (författare)
  • Uppsala universitetMolekylära verktyg (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:PLOS ONE: Public Library of Science (PLoS)9:5, s. e96690-1932-6203

Internetlänk

Hitta via bibliotek

  • PLOS ONE (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy