SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Wijns W)
 

Sökning: WFRF:(Wijns W) > (2010-2014) > (2014) > Moreno R. > A randomized, prosp...

  • Saito, S (författare)

A randomized, prospective, intercontinental evaluation of a bioresorbable polymer sirolimus-eluting coronary stent system : the CENTURY II (Clinical Evaluation of New Terumo Drug-Eluting Coronary Stent System in the Treatment of Patients with Coronary Artery Disease) trial

  • Artikel/kapitelEngelska2014

Förlag, utgivningsår, omfång ...

  • 2014-05-19
  • Oxford University Press (OUP),2014
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-245852
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-245852URI
  • https://doi.org/10.1093/eurheartj/ehu210DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Aim The aim of this study was to establish safety and efficacy of a new sirolimus-eluting stent with bioresorbable polymer, Ultimaster (BP-SES). Sirolimus-eluting stent with bioresorbable polymer was compared with everolimus-eluting, permanent polymer, Xience stent (PP-EES) in the frame of a CENTURY II clinical trial designed to make global clinical data compliant with regulatory requirements in Europe and Japan.Methods and results The CENTURY II is a prospective, multicentre, randomized (1 : 1), single blind, controlled, non-inferiority clinical trial conducted at 58 study sites in Japan, Europe, and Korea. A total of 1123 patients requiring a percutaneous coronary intervention (PCI) procedure, with implantation of drug-eluting stent (DES), were enrolled [total population (TP)]. Randomization of patients was stratified for the subset of patients matching requirements for DES in Japan (Cohort JR, n = 722). Baseline patient demographic and angiographic characteristics were similar in both study arms, with minimal differences between the TP and Cohort JR. The primary endpoint, freedom from target lesion failure (TLF) at 9 months—TLF [composite of cardiac death, target-vessel-related myocardial infarction (MI) and target lesion revascularization]—was 95.6% with BP-SES and 95.1% with PP-EES (Pnon-inferiority<0.0001). Composite of cardiac death and MI rate was 2.9 and 3.8% (P = 0.40) and target vessel revascularization was 4.5% with BP-SES and 4.2% with PP-EES (P = 0.77). The stent thrombosis rate was 0.9% in both arms. In Cohort JR, freedom from TLF was 95.9 and 94.6% (Pnon-inferiority < 0.0005) with BP-SES and PP-EES, respectively.Conclusion The new bioresorbable polymer sirolimus-eluting stent showed safety and efficacy profiles similar to durable polymer everolimus-eluting stent at 9-month follow-up.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Valders-Chavarri, M (författare)
  • Richardt, G (författare)
  • Moreno, R (författare)
  • Iniguez Romo, A (författare)
  • Barbato, E (författare)
  • Carrie, D (författare)
  • Ando, K (författare)
  • Merkely, B (författare)
  • Kornowski, R (författare)
  • Eltchaninoff, H (författare)
  • James, StefanUppsala universitet,Kardiologi,Uppsala kliniska forskningscentrum (UCR),Upsala Clinical Research Center(Swepub:uu)stjam367 (författare)
  • Wijns, W (författare)
  • Uppsala universitetKardiologi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:European Heart Journal: Oxford University Press (OUP)35:30, s. 2021-20310195-668X1522-9645

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy