SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Persson Anders)
 

Search: WFRF:(Persson Anders) > Renal artery stenos...

Renal artery stenosis : extracting quantitative parameters with a mathematical model fitted to magnetic resonance blood flow data

Larsson, Martin (author)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Hälsouniversitetet
Persson, Anders (author)
Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Röntgenkliniken i Linköping
Eriksson, Per (author)
Östergötlands Läns Landsting,Linköpings universitet,Institutionen för medicin och hälsa,Hälsouniversitetet,Njurmedicinska kliniken
show more...
Kihlberg, Johan (author)
Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet
Smedby, Örjan (author)
Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Röntgenkliniken i Linköping
show less...
 (creator_code:org_t)
2007
2008
English.
In: Journal of Magnetic Resonance Imaging. - : John Wiley & Sons. - 1053-1807 .- 1522-2586. ; 27:1, s. 140-147
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Purpose: To investigate the feasibility of quantitative parameter extraction from a mathematical model fitted to renal artery magnetic resonance flow data.Material and methods: Sixteen subjects, 8 patients and 8 normal controls, were examined with cine phase-contrast velocity measurements, and blood flow data from the aorta and both renal arteries were extracted by means of contour detection. A mathematical model with eight parameters describing the time, duration and amplitude of the systolic acceleration and the diastolic deceleration was fitted to the aorta and renal artery blood flow data from each subject. The curve fitting was evaluated with R2 values. Statistical analysis was performed with unpaired Wilcoxon tests and stepwise logistic regression.Results: Three data sets out of 48 yielded R2 values below 0.80 and were considered unreliable for parameter estimation. Basal flow was significantly, and systolic peak amplitude almost significantly, lower in stenotic arteries. Logistic regression indicated that two parameters describing basal flow and the duration of acceleration can accurately predict stenosis.Conclusion: The results suggest that it is technically feasible to fit a mathematical model to renal blood flow data, extracting quantitative parameters that may prove useful for quantification and diagnosis of renal artery stenosis.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Keyword

Flow measurement
Magnetic Resonance Angiography
Blood flow
Renal artery stenosis
MEDICINE
MEDICIN

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Larsson, Martin
Persson, Anders
Eriksson, Per
Kihlberg, Johan
Smedby, Örjan
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Medical Image Pr ...
Articles in the publication
Journal of Magne ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view